25
③
Turn the leveling screw C to move the bubble to the center of the circular vial.
4) Precisely leveling by using the plate vial
①
Rotate the instrument horizontally by loosening the Horizontal Clamp Screw
and place the plate vial parallel to the line connecting leveling screw A and B, and then
bring the bubble to the center of the plate vial by turning the leveling screws A and B.
②
Rotate the instrument 90º
(100g) around its vertical axis and turn the
remaining leveling screw or leveling C to center the bubble once more.
③
Repeat the steps
①②
for each 90º
(100g) rotation of the instrument and check