46
6.2.6 Distance Measurement (Single/N-Time Measurement)
When the number of times for measurement is preset, the instrument measures the
distance according to the specified number or times. The average result will be
displayed.
When presetting the number of times as 1, it does not display the average distance
because it is just single measurement; Single measurement is default factory setting.
1
)
Example
:
Setting the number of times
OPERATION STEPS
KEY
DISPLAY
①
In distance measuring Mode,
click [Mode] to enter EDM
Mode setting.
System defaults as Fine[s].
[Mode]
②
Click Fine [N] or press [▲]/
[▼], a Times column displays on
the upper right screen. Input the
times of N-time measurement.
[Fine[N]]
Input times
③
Click [Enter]. Sight the target,
system start survey based on the
setting set just now.
[Enter]
※
1) To return to Angle measurement mode, click “Angle” key.