22
Rotate the leveling screws while observing electric circular bubble. After the bubble
centered at the cross point, press [Back] to return the previous interface.
2. Set the Temperature ,Pressure, Atmospheric Correction Value
(
PPM
)
and Prism
constant value
(
PSM
)
Click [Atmos] to view the Temperature, Pressure, PPM and PSM. To modify
parameters, point the cursor to the textbox by stylus, and input the new value. Please
Refer to “14. SYSTEM SETTINGS” for the detail.
3. Set the target type, illumination of crosshair and check the signal intensity.
Click [Target], target type, illumination of cross hair, etc. can be set.
Setting of target type:
There are two measuring modes for KTS-470 series: visible laser EDM and invisible