40
meter)
If the pressure unit adopted is mmHg: make conversion with:
1hPa = 0.75mmHg.
●
The standard atmospheric condition of KTS-470R Series (e.g. the atmospheric
condition under which the atmospheric correction value of the instrument is zero ) :
Pressure
:
1013 hPa
Temperature: 20
℃
If regardless of atmospheric correction, please set PPM value as 0.
OPERATION STEPS
OPERATION
DISPLAY
(1)
In the menu of total station,
click “Meas.Setup” and then
click “Atmospheric
Parameters”.
[Meas.Setup]
[Atmospheric
parameters]
②
Current Atmospheric
Parameters display on the
screen. use stylus and
input the new data. For
instance, set the temperature
as 26°C
Input
Temperature
③
According to the same steps,
input the value of Air pressure.
click the “Save” after finishing
setting.
Input Pressure
+
[Save]