26
whether the bubble is correctly centered in all directions.
2. Centering by using the optical plummet
1) Set tripod
Set up tripod to suitable height, ensure equal length of three legs, spread and
make tripod head parallel to the ground, and place it right above the measurement
station point. Prop up tripod on the ground and fix one leg.
2) Install instrument and collimate the point
Set instrument carefully on tripod, tighten the central connecting screw and
adjust optical plummet to make the reticle distinctly. Hold the other two unfixed legs
with both hands and adjust position of these two legs through observation of optical
plummet. As it approximately aims at the station point, make all three legs fixed on the
ground. Adjust three leg screws of the instrument to make optical plummet collimate
precisely to the station point.
3) Use circular vial to roughly level the instrument.
Adjust length of three legs of tripod; make the circular vial bubble of the
instrument in the middle.
4) Use plate vial to level the instrument accurately.
①
Rotate the instrument horizontally by loosening the Horizontal Clamp Screw
and place the plate vial parallel to the line connecting leveling screw A and B, and then
bring the bubble to the center of the plate vial by turning the leveling screws A and B.
②
Rotate the instrument 90
℃
, make it perpendicular to the connecting line of
level screws A and B. Turn level screw C to make the bubble of the plate vial in the
middle.
5) Precisely centering and leveling
Through observation of optical plummet, slightly loosen the central
connecting screw and move the instrument evenly (Don‟t rotate the instrument),
making the instrument precisely collimating to the station point. Then tighten the
central connecting screw and level the instrument precisely again.
Repeat this operation till the instrument collimate precisely to the
measurement station point.
5.3 BATTERY INFORMATION
Notice:
①
the battery operating time will vary depending on the environmental
conditions such as ambient temperature, charging time, the number of times of
charging and discharging etc. It is recommended for safety to charge the battery
beforehand or to prepare spare full charged batteries.
②
the battery icon shows the power level regarding the current measurement
mode. The distance measurement mode consumes more power than angle