73
Example
7-8
: Internal
Multi-position
control mode
A motor needs to go eight position sections. In position section 0, it should reach the 5000 pulse location at
the speed of 100RPM.In position section 1, it should reach the 15000 pulse location at the speed of
150RPM.In position section 2, it should reach the 28500 pulse location at the speed of 175RPM.In position
section 3, it should reach the -105000 pulse location at the speed of 200RPM. In position section 4, it should
reach the -20680 pulse location at the speed of 300RPM. In position section 5, it should reach the -30550
pulse location at the speed of 325RPM. In position section 6, it should reach the 850 pulse location at the
speed of 275RPM. In position section 7, it should reach the 15000 pulse location at the speed of 460RPM.
Table 7-21 Internal Multi-position Control Mode Demand
DIN1
The driver is enabled, the motor shaft is locked
DIN3
Driver working mode
(
invalid 1
,
valid-3
)
DIN4
Internal position 0
DIN5
Internal position 1
DIN6
Internal position 2
DIN6:DIN5:DIN4=0:0:0
Select position and speed in section 0
DIN6:DIN5:DIN4=0:0:1
Select position and speed in section 1
DIN6:DIN5:DIN4=0:1:0
Select position and speed in section 2
DIN6:DIN5:DIN4=0:1:1
Select position and speed in section 3
DIN6:DIN5:DIN4=1:0:0
Select position and speed in section 4
DIN6:DIN5:DIN4=1:0:1
Select position and speed in section 5
DIN6:DIN5:DIN4=1:1:0
Select position and speed in section 6
DIN6:DIN5:DIN4=1:1:1
Select position and speed in section 7
DIN6
Activate command
(
execute the selected
position section
)
1.
Define the meanings of the input points:
Table 7-22 Internal Multi-position Control Mode Configuration
Numberic
display
Variable name
Configuration way
d3.01
Din1_Function
000.1
(
Driver enabled
)
d3.03
Din3_Function
000.4
(
Set driver mode
)
d3.04
Din4_Function
040.0
(
Internal position control 0
)
d3.05
Din5_Function
080.0
(
Internal position control 1
)
d3.06
Din6_Function
800.2 (Internal position control 2)
d3.07
Din7_Function
400.0
(
Activate command
)
d3.16
Din_mode 0
Set 0001
(
1
)
Mode
Internal
Multi-position
control mode
d3.17
Din_mode 1
Set 0.004 (-4) Mode
Pulse-control mode
Содержание CD2S Series
Страница 7: ...7...
Страница 8: ...8 1 3 3 Power Brake and Encoder cable of Motors...
Страница 12: ...12 Fig 2 3 Installation direction...
Страница 15: ...15 3 1 2 Wiring Diagram Fig 3 1 Wiring diagram of CD2S driver...
Страница 16: ...16 3 1 3 X1 interface of CD2S Driver Fig 3 2 X1 interface Fig 3 3 Wiring diagram of X1 interface...
Страница 23: ...23 Fig 4 3 Separate regulation of bits...
Страница 82: ...82...
Страница 96: ...96 8 4 Debugging example 8 4 1 Oscilloscope 1 Enter oscilloscope 2 Parameters for Oscilloscope...
Страница 98: ...98 In Auto Reverse mode Kvp 110...
Страница 100: ...100 The oscilloscope is as following max following error is 69 inc Fig 2 Kpp 30 Vff 100...
Страница 101: ...101 The oscilloscope is as following max following error is 53 inc Fig 3 Kpp 30 Vff 50...
Страница 102: ...102 The oscilloscope is as following max following error is 230 inc...