SENS:DLOG:CURR:RANG 0.1, (@1)
SENS:DLOG:VOLT:RANG 5, (@1)
Data Logger Trigger
Once the Data Logger has been triggered, do not change the display to Scope View or
Meter View; otherwise Data Logger will stop.
From the front panel:
Select the Trigger button to configure the trigger properties. The Data Logger uses triggers to
synchronize itself with an external event.
The Source dropdown list lets you select a trigger source. The same trigger source will be used to
trigger all of the outputs that have been configured for data logging. Depending upon the selected
trigger source, you can trigger the Data Logger as follows:
Trigger Source
Description
Voltage <1-4> level
Current <1-4> level
Triggers the Data Logger when the voltage or current of the corresponding output passes
through the specified level.
Run/Stop key
Triggers the Data Logger when the Run/Stop key is pressed. This is the default trigger source.
Arb Run/Stop key
Triggers the Data Logger when the Arb Run/Stop key is pressed.
Output On/Off key
Triggers the Data Logger when any of the Output On/Off keys are pressed. Also applies to the All
Outputs On/Off key.
BNC Trigger In
Provide a low-true signal to the BNC trigger input connector. The signal must have a minimum
pulse width of 2 microseconds. Selecting BNC Trigger In also enables any digital I/O pins con-
figured as Trigger Outputs (see Appendix C).
Remote Command
Send a trigger command over one of the three interfaces (i.e. *TRG).
If a trigger source is grayed out, it is unavailable. For example, current levels are not available as
trigger sources on outputs that have been grouped (paralleled). Note also that a trace must be turned
on for it to be used as a trigger source.
4 Using the Measurement Functions
154
Keysight N6705C Operating and Service Guide
Содержание N6705C
Страница 76: ......
Страница 353: ...Status Diagram Keysight N6705C Operating and Service Guide 353 7 SCPI Programming Reference ...
Страница 376: ...8 Verification and Calibration 376 Keysight N6705C Operating and Service Guide ...
Страница 389: ...Keysight N6705C Operating and Service Guide 389 8 Verification and Calibration ...
Страница 434: ......
Страница 438: ...9 Service and Maintenance 438 Keysight N6705C Operating and Service Guide ...
Страница 459: ...Overall Troubleshooting Keysight N6705C Operating and Service Guide 459 9 Service and Maintenance ...
Страница 460: ...9 Service and Maintenance 460 Keysight N6705C Operating and Service Guide ...
Страница 461: ...Keysight N6705C Operating and Service Guide 461 9 Service and Maintenance ...
Страница 462: ...9 Service and Maintenance 462 Keysight N6705C Operating and Service Guide ...
Страница 463: ...Keysight N6705C Operating and Service Guide 463 9 Service and Maintenance ...
Страница 470: ...Mezzanine Parts 9 Service and Maintenance 470 Keysight N6705C Operating and Service Guide ...
Страница 471: ...Front Panel Parts Keysight N6705C Operating and Service Guide 471 9 Service and Maintenance ...
Страница 476: ......