:MARKer<1|2>
:POINt <
value
>
Positions the data log markers
:OFFSet <
value
>
Sets trigger offset as a percent from start of data log duration.
:PERiod <
value
>
Sets the interval between samples (replaces TINTerval).
:TIMe <
value
>
Sets the duration of the internal data log in seconds
:TINTerval <
value
>
Sets the interval between samples (for backward compatibility)
:VOLTage
[:DC]
:RANge
[:UPPer] <
value
>, (@chanlist)
Selects the internal data log voltage measurement range.
:AUTO 0|OFF|1|ON, (@chanlist) Enables/disables seamless measurement autoranging. (N6781A, N6782A)
:ELOG
:CURRent
[:DC]
:RANge
[:UPPer] <
value
>, (@chanlist)
Selects the external data log current measurement range.
:AUTO 0|OFF|1|ON, (@chanlist) Enables/disables seamless Elog measurement autoranging.
(only on N6781A/82A/85A/86A)
:FUNCtion
:CURRent 0|OFF|1|ON, (@chanlist)
Enables/disables current data logging.
:MINMax 0|OFF|1|ON, (@chanlist)
Enables/disables min/max current data logging.
:VOLTage 0|OFF|1|ON, (@chanlist)
Enables/disables voltage data logging.
:MINMax 0|OFF|1|ON, (@chanlist)
Enables/disables min/max voltage data logging.
:PERiod <
value
>, (@chanlist)
Sets the integration time of the external data log measurement.
:VOLTage
[:DC]
:RANge
[:UPPer] <
value
>, (@chanlist)
Selects the external data log voltage measurement range.
:AUTO 0|OFF|1|ON, (@chanlist) Enables/disables seamless Elog measurement autoranging. (N6781A, N6782A)
:FUNCtion <
"function"
>, (@chanlist)
Selects the measurement function (for backward compatibility)
:CURRent 0|OFF|1|ON, (@chanlist)
Enables/disables current measurements (replaces FUNCtion)
:VOLTage 0|OFF|1|ON, (@chanlist)
Enables/disables voltage measurements (replaces FUNCtion)
:INPut <MAIN|AUXiliary>, (@chanlist)
Selects the voltage measurement input. (only on N6781A, N6785A)
:HISTogram
:CURRent
(HISTogram commands only apply to models N6781A/82A/85A/86A)
[:DC]
:BIN
:GAIN? 8|0.0039, (@chanlist)
Queries the LSB of the histogram in amperes per bin
:OFFSet? 8|0.0039, (@chanlist) Queries the weight of the histogram in amperes
:RANGes? (@chanlist)
Queries the values of the bin ranges
:RANge
[:UPPer] <
value
>, (@chanlist)
Selects the internal data log voltage measurement range.
:AUTO 0|OFF|1|ON, (@chanlist) Enables/disables seamless Elog measurement autoranging.
:FUNCtion
Keysight N6705C Operating and Service Guide
31
1 Quick Reference
Содержание N6705C
Страница 76: ......
Страница 353: ...Status Diagram Keysight N6705C Operating and Service Guide 353 7 SCPI Programming Reference ...
Страница 376: ...8 Verification and Calibration 376 Keysight N6705C Operating and Service Guide ...
Страница 389: ...Keysight N6705C Operating and Service Guide 389 8 Verification and Calibration ...
Страница 434: ......
Страница 438: ...9 Service and Maintenance 438 Keysight N6705C Operating and Service Guide ...
Страница 459: ...Overall Troubleshooting Keysight N6705C Operating and Service Guide 459 9 Service and Maintenance ...
Страница 460: ...9 Service and Maintenance 460 Keysight N6705C Operating and Service Guide ...
Страница 461: ...Keysight N6705C Operating and Service Guide 461 9 Service and Maintenance ...
Страница 462: ...9 Service and Maintenance 462 Keysight N6705C Operating and Service Guide ...
Страница 463: ...Keysight N6705C Operating and Service Guide 463 9 Service and Maintenance ...
Страница 470: ...Mezzanine Parts 9 Service and Maintenance 470 Keysight N6705C Operating and Service Guide ...
Страница 471: ...Front Panel Parts Keysight N6705C Operating and Service Guide 471 9 Service and Maintenance ...
Страница 476: ......