What's New
1
Keysight InfiniiVision M9241/42/43A PXIe Oscilloscopes SCPI Programmer's Guide
45
Changed
Commands
Command
Differences From InfiniiVision 3000T X-Series Oscilloscopes
:CALibrate:OUTPut (see
)
The OFF option is now available.
:DISPlay:ANNotation<n>:BACK
The TRANsparent option is not available.
:DISPlay:DATA? (see
)
The GRAYscale palette option is not available. Also, the
background color invert is not available because there is no
:HARDcopy:INKSaver command.
:FUNCtion<m>:OPERation (see
)
The BTIMing and BSTate operations are not available.
:SBUS<n>:CAN:SOURce (see
)
The EXTernal trigger input source is not available.
:SBUS<n>:IIC[:SOURce]:CLOCk
(see
)
The EXTernal trigger input source is not available.
:SBUS<n>:IIC[:SOURce]:DATA?
(see
)
The EXTernal trigger input source is not available.
:SBUS<n>:LIN:SOURce (see
)
The EXTernal trigger input source is not available.
:SBUS<n>:MODE (see
)
The FLEXray, I2S, and SPI modes are not available.
:SBUS<n>:SENT:SOURce (see
)
The EXTernal trigger input source is not available.
:SBUS<n>:UART:SOURce:RX
(see
)
The EXTernal trigger input source is not available.
:SBUS<n>:UART:SOURce:TX
(see
)
The EXTernal trigger input source is not available.
:SYSTem:DATE (see
The command for setting the date is no longer available, but the
query for getting the date is still available.
:SYSTem:TIME (see
The command for setting the time is no longer available, but the
query for getting the time is still available.
:SYSTem:RLOGger:TRANsparen
t (see
)
OFF is the only valid option.
:TIMebase:MODE (see
The XY and ROLL modes are not available.
:TRIGger:MODE (see
The USB mode is not available.
:TRIGger[:EDGE]:SOURce (see
The LINE source is not available.
Содержание InfiniiVision M9241A
Страница 1: ...Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide ...
Страница 52: ...52 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 2 Setting Up ...
Страница 178: ...178 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 5 Commands Quick Reference ...
Страница 246: ...246 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 7 Root Commands ...
Страница 268: ...268 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 8 ACQuire Commands ...
Страница 280: ...280 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 9 CALibrate Commands ...
Страница 354: ...354 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 15 EXTernal Trigger Commands ...
Страница 412: ...412 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 17 FUNCtion m Commands ...
Страница 416: ...416 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 18 HCOPY Commands ...
Страница 442: ...442 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 20 MARKer Commands ...
Страница 588: ...588 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 23 MTESt Commands ...
Страница 692: ...692 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 24 POWer Commands ...
Страница 1062: ...1062 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 30 TIMebase Commands ...
Страница 1250: ...1250 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 33 WGEN w Commands ...
Страница 1306: ...1306 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 35 Obsolete and Discontinued Commands ...
Страница 1314: ...1314 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 36 Error Messages ...
Страница 1376: ...1376 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 39 More About Oscilloscope Commands ...