:SBUS<n>:M1553:TRIGger:TYPE
Command Syntax
:SBUS<n>:M1553:TRIGger:TYPE <type>
<type> ::= {DSTArt | DSTOp | CSTArt | CSTOp | RTA | PERRor | SERRor
| MERRor | RTA11}
The :SBUS<n>:M1553:TRIGger:TYPE command specifies the type of
MIL-STD-1553 trigger to be used:
• DSTArt — (Data Word Start) triggers on the start of a Data word (at the end of a
valid Data Sync pulse).
• DSTOp — (Data Word Stop) triggers on the end of a Data word.
• CSTArt — (Command/Status Word Start) triggers on the start of
Command/Status word (at the end of a valid C/S Sync pulse).
• CSTOp — (Command/Status Word Stop) triggers on the end of a
Command/Status word.
• RTA — (Remote Terminal Address) triggers if the RTA of the Command/Status
word matches the specified value. The value is specified in hex.
• RTA11 — (RTA + 11 Bits) triggers if the RTA and the remaining 11 bits match the
specified criteria. The RTA can be specified as a hex value, and the remaining 11
bits can be specified as a 1, 0, or X (don't care).
• PERRor — (Parity Error) triggers if the (odd) parity bit is incorrect for the data in
the word.
• MERRor — (Manchester Error) triggers if a Manchester encoding error is
detected.
• SERRor — (Sync Error) triggers if an invalid Sync pulse is found.
Query Syntax
:SBUS<n>:M1553:TRIGger:TYPE?
The :SBUS<n>:M1553:TRIGger:TYPE? query returns the currently set
MIL-STD-1553 trigger type.
Return Format
<type><NL>
<type> ::= {DSTA | DSTO | CSTA | CSTO | RTA | PERR | SERR
| MERR | RTA11}
See Also
•
"Introduction to :TRIGger Commands"
•
•
":SBUS<n>:M1553:TRIGger:PATTern:DATA"
•
Содержание InfiniiVision M9241A
Страница 1: ...Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide ...
Страница 52: ...52 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 2 Setting Up ...
Страница 178: ...178 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 5 Commands Quick Reference ...
Страница 246: ...246 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 7 Root Commands ...
Страница 268: ...268 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 8 ACQuire Commands ...
Страница 280: ...280 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 9 CALibrate Commands ...
Страница 354: ...354 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 15 EXTernal Trigger Commands ...
Страница 412: ...412 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 17 FUNCtion m Commands ...
Страница 416: ...416 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 18 HCOPY Commands ...
Страница 442: ...442 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 20 MARKer Commands ...
Страница 588: ...588 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 23 MTESt Commands ...
Страница 692: ...692 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 24 POWer Commands ...
Страница 1062: ...1062 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 30 TIMebase Commands ...
Страница 1250: ...1250 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 33 WGEN w Commands ...
Страница 1306: ...1306 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 35 Obsolete and Discontinued Commands ...
Страница 1314: ...1314 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 36 Error Messages ...
Страница 1376: ...1376 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 39 More About Oscilloscope Commands ...