4
Sequential (Blocking) vs. Overlapped Commands
Pausing Programs
Until Sequential
(Blocking)
Commands are
Complete
Sequential (blocking) commands do not prevent additional commands from being
sent to the queue or cause the remote program to wait. For example, if your
program does something like:
myScope.WriteString ":DIGitize"
Debug.Print "Signal acquired."
The "Signal acquired" message will be written immediately after the :DIGitize is
sent, not after the acquisition and processing is complete.
To pause the program until a sequential (blocking) command is complete, you
must wait for a query result after the sequential (blocking) command. For example,
in this case:
Public strQueryResult As String
myScope.WriteString ":DIGitize;*OPC?"
strQueryResult = myScope.ReadString
Debug.Print "Signal acquired."
The "Signal acquired" message will be written after the acquisition and processing
is complete. The *OPC? query is appended to :DIGitize with a semi-colon (;), which
essentially ties it to the same thread in the parser. It is immediately dealt with once
:DIGitize finishes and gives a "1" back to the program (whether the program uses it
or not), allowing the program to move on.
When using a query to wait until a sequential (blocking) command is complete, it
is possible for the sequential (blocking) command execution to take longer than
the I/O timeout, in which case, there will be a timeout error while waiting for the
query results. You can increase the I/O timeout or have your program poll the
Status Byte Register using the IO libraries' unblocked ReadSTB function to wait for
execution completion.
Using Device Clear
to Abort a
Sequential
(Blocking)
Command
When sequential (blocking) commands take too long or fail to complete for some
reason, you can send a Device Clear over the bus to clear the input buffer and
output queue, reset the parser, and clear any pending commands.
See Also
•
•
"*ESR (Standard Event Status Register)"
•
Содержание InfiniiVision M9241A
Страница 1: ...Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide ...
Страница 52: ...52 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 2 Setting Up ...
Страница 178: ...178 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 5 Commands Quick Reference ...
Страница 246: ...246 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 7 Root Commands ...
Страница 268: ...268 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 8 ACQuire Commands ...
Страница 280: ...280 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 9 CALibrate Commands ...
Страница 354: ...354 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 15 EXTernal Trigger Commands ...
Страница 412: ...412 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 17 FUNCtion m Commands ...
Страница 416: ...416 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 18 HCOPY Commands ...
Страница 442: ...442 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 20 MARKer Commands ...
Страница 588: ...588 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 23 MTESt Commands ...
Страница 692: ...692 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 24 POWer Commands ...
Страница 1062: ...1062 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 30 TIMebase Commands ...
Страница 1250: ...1250 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 33 WGEN w Commands ...
Страница 1306: ...1306 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 35 Obsolete and Discontinued Commands ...
Страница 1314: ...1314 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 36 Error Messages ...
Страница 1376: ...1376 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 39 More About Oscilloscope Commands ...