802
Keysight InfiniiVision M9241/42/43A PXIe Oscilloscopes SCPI Programmer's Guide
27
:SBUS<n> Commands
:SBUS<n>:CXPI:TRIGger:PATTern:INFO:DLC
Command Syntax
:SBUS<n>:CXPI:TRIGger:PATTern:INFO:DLC <dlc>
<dlc> ::= integer between -1 (don't care) and 15, in NR1 format,
when trigger is in DATA mode.
<dlc> ::= integer between -1 (don't care) and 255, in NR1 format,
when trigger is in LDATa mode.
For the trigger types that let you trigger on data, the
:SBUS<n>:CXPI:TRIGger:PATTern:INFO:DLC command specifies the data length
code of the CXPI frame you wish to trigger on.
This will also affect the number of data bytes you can specify in the trigger.
Query Syntax
:SBUS<n>:CXPI:TRIGger:PATTern:INFO:DLC?
The :SBUS<n>:CXPI:TRIGger:PATTern:INFO:DLC? query returns the DLC trigger
value setting.
Return Format
<dlc><NL>
<dlc> ::= integer between -1 (don't care) and 15, in NR1 format,
when trigger is in DATA mode.
<dlc> ::= integer between -1 (don't care) and 255, in NR1 format,
when trigger is in LDATa mode.
See Also
•
•
":SBUS<n>:CXPI:TRIGger:IDFilter"
•
•
":SBUS<n>:CXPI:TRIGger:PATTern:DATA"
•
":SBUS<n>:CXPI:TRIGger:PATTern:DATA:LENGth"
•
":SBUS<n>:CXPI:TRIGger:PATTern:DATA:STARt"
•
":SBUS<n>:CXPI:TRIGger:PATTern:ID"
•
":SBUS<n>:CXPI:TRIGger:PATTern:INFO:CT"
•
Содержание InfiniiVision M9241A
Страница 1: ...Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide ...
Страница 52: ...52 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 2 Setting Up ...
Страница 178: ...178 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 5 Commands Quick Reference ...
Страница 246: ...246 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 7 Root Commands ...
Страница 268: ...268 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 8 ACQuire Commands ...
Страница 280: ...280 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 9 CALibrate Commands ...
Страница 354: ...354 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 15 EXTernal Trigger Commands ...
Страница 412: ...412 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 17 FUNCtion m Commands ...
Страница 416: ...416 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 18 HCOPY Commands ...
Страница 442: ...442 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 20 MARKer Commands ...
Страница 588: ...588 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 23 MTESt Commands ...
Страница 692: ...692 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 24 POWer Commands ...
Страница 1062: ...1062 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 30 TIMebase Commands ...
Страница 1250: ...1250 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 33 WGEN w Commands ...
Страница 1306: ...1306 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 35 Obsolete and Discontinued Commands ...
Страница 1314: ...1314 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 36 Error Messages ...
Страница 1376: ...1376 Keysight InfiniiVision M9241 42 43A PXIe Oscilloscopes SCPI Programmer s Guide 39 More About Oscilloscope Commands ...