3-14
No.
Item
Measuring
instruments &
Input signals
Mode
Measuring point (
*
)
Adjustment parts (
-
)
Adjustment level (
+
)
Adjustment procedure
3.4.3
MONITOR LCD adjustment
For the MONITOR LCD adjustment, the following adjustment are required only. Other adjustment items should be default
value.
1
COMMON DC
adjustment
ADJUST MENU
*
MONITOR LCD
-
JOG dial
+
Minimize the flicker
(1) Press the USER 1/2 button to select ADJUST
MENU No.78,”COMMON DC”.
(2) Set the MONITOR LCD to field invert mode,
rotate the JOG dial to adjust to the specified
level.
(3) Press the JOG dial to store the adjustment
data.
2
VCO adjust-
ment
ADJUST MENU
*
MONITOR LCD
-
JOG dial
+
Most stable point
for monitor screen
(1) Press the USER 1/2 button to select ADJUST
MENU No.80.”VCO FINE”.
(2) Rotate the JOG dial to adjust to the specified
level.
3
H-POSITION
adjustment
ADJUST MENU
*
MONITOR LCD
-
JOG dial
+
Screen centering
(1) Press the USER 1/2 button to select ADJUST
MENU No.83,”H POSITION”.
(2) Rotate the JOG dial to adjust the marker to
horizontal center of the screen.
(3) Press the JOG dial to store the adjustment
data.
Gray scale chart
NOTE:
If adjustment cannot be done, change AD-
JUST MENU No. 82 “VCO COARSE” to 3 or
5 and readjust.
(3) Press the JOG dial to store the adjustment
data.
OK
NG
OK
NG
50 %
50 %
—
—