1-15
D R UM
C L E A R
– – –
H O U R M E T E R [ 1 / 2 ]
– – –
T O T A L
D R UM
0 0 0 0 0 0 H
F A N
0 0 0 0 0 0 H
P O W E R
0 0 0 0 0 0 H
C A P S T A N
0 0 0 0 0 0 H
S E A C H
0 0 0 H 0 0 M
F F / R E W
0 0 0 H 0 0 M
N E X T
P A G E
P A G E
B A C K
L O A D I N G
0 0 0 0 0 0 0
– – –
H O U R M E T E R [ 2 / 2 ]
– – –
E J E C T
0 0 0 0 0 0 0
F W D / R E V
0 0 0 0 0 0 0
C L E A N I N G
T A P E
0 0 0 0 0 0 0
P A G E
B A C K
Fig. 1-5-10 (1)
Fig. 1-5-10 (2)
1.5.10
HOUR METER
In a service menu, place the cursor on “HOUR METER ” and
push the SHUTTER dial to display the HOUR METER menu.
1.5.11
ERROR HISTORY
In a service menu, place the cursor on “ERROR HISTORY ” and
push the SHUTTER dial to display the ERROR HISTORY menu.
– – –
E R R O R
H I S T O R Y
– – –
( H I S T O R Y - 1 )
7 1 0 1
C A P MO T O R
F A I L U R E
( H I S T O R Y - 2 )
7 1 0 1
C A P MO T O R
F A I L U R E
( H I S T O R Y - 3 )
7 1 0 1
C A P MO T O R
F A I L U R E
( H I S T O R Y - 4 )
7 1 0 1
C A P MO T O R
F A I L U R E
C L E A R
C A N C E L
P A G E
B A C K
Fig. 1-5-12 (1)
1.5.12 Detail indication of ERROR HISTORY
In a ERROR HISTORY display, place a cursor onto the item and
push SHUTTER dial, then detail display (MECHANISM INFO)
picture will be shown.
MECHANISM INFO has 2 pages.
Operation ways are almost same as CAMERA 1 menu, so please refer it.
000000 Displays the drum hour
meter(maintenance for drum)
CLEAR Resets the drum hour meter.
000000 Displays the total hour meter.
CLEAR Resets the total drum hour meter.
(This does not work unless the special
setting)
000000 Displays the fan hour meter.
CLEAR Resets the fan hour meter.
000000 Displays the power hour meter.
CLEAR Resets the power hour meter.
000000 Displays the capstan hour meter.
CLEAR Resets the capstan hour meter.
000000 Displays the search hour meter.
CLEAR Resets the search hour meter.
000000 Displays the FF/REW hour meter.
CLEAR Resets the FF/REW hour meter.
000000 Displays the loading count.
CLEAR Resets the loading count.
000000 Displays the eject count.
CLEAR Resets the eject count.
000000 Displays the forward/reverse
switching count.
CLEAR Resets the forward/reverse switching
count.
000000 Displays the cleaning tape working
count.
CLEAR Resets the cleaning tape working
count.
Item
Parameter
DRUM
TOTAL DRUM
FAN
POWER
CAPSTAN
SEARCH
FF/REV
LOADING
EJECT
FWD/REV
CLEANING TAPE
Table 1-5-10
Fig. 1-5-11
(1) Rotate the SHUTTER dial to move the cursor onto the item
to show details.
(2) Push the SHUTTER dial so that the details of ERROR HIS-
TORY is shown.
(3) Rotate the SHUTTER dial to move cursor onto the “CLEAR”,
push the SHUTTER dial, then ERROR HISTORY will be de-
leted.
Fig. 1-5-12 (2)
– – –
M E C H A N I S M
I N F 0
1 / 2 – –
P . T M
0 0 0 0 0 0 H
S Y S MO D E : P L A Y ( 0 1 . 0 0 )
M S D MO D E : P L A Y ( 0 1 . 0 0 )
– > S T O P ( 0 0 . 0 0 )
L A S T
K E Y : P L A Y ( 0 1 . 0 0 )
T A P E
R E M [ 0 0 0 0 ]
D E W
[ 0 0 ]
T E M P [ 0 0 ]
D I A M E T E R
T U [ 0 0 ] S P [ 0 0 ]
N E X T
P A G E
P A G E
B A C K
– – –
M E C H A N I S M
I N F 0
2 / 2 – –
M . P O S I
B R K 2 F A S T > B R K 2 F A S T
H . P O S I
I N I T
> C A S S
I N
C A P [ O F F
F W D ] R E L [ O F F
F W D ]
T U
[ O N ]
S P [ O F F ]
D RM [ O F F ]
D R V [ 0 0 ] C A P V [ 0 0 ]
R E L V [ 0 0 ]
MC V [ 0 0 ] R E L I [ 0 0 ]
B G N [ O F F ] E N D [ O N ]
C A S [ O F F ]
S T D [ O F F ]
H W [ O F F ]
H W 2 [ O F F ]
S P L [ O F F ] T H I N [ O N ]
P A G E
B A C K
Note :
ERROR HISTORY was stored from “HISTORY-1” box to
“HISTORY-4”box. Latest error was stored “HISTORY-4”
box, and if there will be occur another error then latest error
history will be rewrite on “HISTORY-4”. From “HISTORY-
1” to “HISTORY-3” will not rewrite, except to “CLEAR”
operation.