1-10
䡵
Details on correctable white blemish
Up to 127 errors with composite video levels of 50mV or
more can be corrected. No limitation of errors per line within
127 however, the maximum consecutive errors are 4 and
the correction results may be inferior to the case of single
error correction.
Oblique noise may be observed on the screen during white
blemish detection. This is due to the principles of error cor-
rection and is not a malfunction.
White blemish can be detected in the following area.
*1: This mode is automatically set to ON when the power
is turned on.
The OFF mode is enabled only after it is set to OFF at
this screen until the power is turned off.
Table 1-5-4
100%
100%
– – –
C A M E R A 2
– – –
P I X E L C OM P E N
O N
T E S T
S I G N A L
O F F
P A G E
B A C K
Item
Parameter
PIXEL
COMPEN
*
1
( indicates the factory setting.)
OFF
Does not correct the detected white
blemish.
ON
Corrects the detected white blemish.
CHECK Light up the pixels which are the
detected white blemish.
Operation ways are almost same as CAMERA 1 MENU, so
please refer it.
1.5.4
CAMERA 2 menu
(1) In a service menu, place the cursor on “CAMERA 2” and
push the SHUTTER dial to display the CAMERA2 menu.
Fig. 1-5-4
Fig. 1-5-3 (5)
Open the Service MENU, select "CAMERA1", "PIXEL
COMPEN DET", "EXECUTE" and push the SHUTTER dial, then
CCD white blemish detect operation start automatically.
At this time, the lens is closed and the camera is in the SLOW
SHUTTER
mode.
– – –
C A M E R A 1
– – –
L C D
L / R
R E V E R S E
O F F
F A S
A U D I O
A U T O
A L C MO D E
A L C + E E I
E E I
M A X
1 / 2 4 0
I R I S
E N F
A U T O
O N
P I X E L
C OM P E N
D E T
E X E C U I T
P A G E
B A C K
Fig. 1-5-3 (3)
After completing white blemish detection, return "REC" and
"FRAME RATE" setting to original one's.
P I X E L C OM P E N
E N D
T U R N
P OW E R O F F
A N D O N
A G A I N
Fig. 1-5-3 (4)
If any errors occurs during the detection operation, an error mes-
sage is displayed , and return to MENU display.
When the white blemish detection completes, the result data
is stored in the memory of CPU,
end message is shown as below, then please turn off.
Message
Treatment
Error details
LENS NOT
CLOSED?
The lens does not
close for detection.
No result is stored in
the EEPROM.
COUNT OVER
The number exceeds
the specified count.
Only the specified
count of data is
stored in the
EEPROM.
Table 1-5-3 (2)