3-5
No.
Item
Measuring
instruments &
Input signals
Mode
Measuring point (
*
)
Adjustment parts (
-
)
Adjustment level (
+
)
Adjustment procedure
1
FH
adjustment
Frequency
counter
ADJUST MENU
*
TP[FH] Rewrite
board
-
JOG dial
+
27,000,000 ± 30Hz
(1) Press the USER 1/2 button to select ADJUST
MENU No.2 ”27MHz CAM”.(Color bar signal
will be output automatically)
(2) Push the JOG dial button so that “*” blinks,
and then rotate the JOG dial to adjust to the
specified value.
(3) Press the JOG dial to store the adjustment
data.
3.4 CAMERA ADJUSTMENTS
3.4.1
Camera adjustments
2
ENCODER
adjustment
(COMPOSITE)
Oscilloscope
ADJUST MENU
*
VIDEO OUT
-
JOG dial
+
VIDEO level
1.000Vp-p
(1) Press the USER 1/2 button to select ADJUST
MENU No.10 ”Y LEVEL (COMPOSITE)” .
(2) Rotate the JOG dial to the specified value.
(3) Press the JOG dial to store the adjustment
data.
3
ENCODER
adjustment
(COMPONENT)
Oscilloscope
ADJUST MENU
(1) Press the USER 1/2 button to select ADJUST
MENU No.12 ”Y LEVEL (COMPONENT)” .
(2) Rotate the JOG dial to the specified value.
(3) Press the JOG dial to store the adjustment
data.
(4) Press the USER 1/2 button to select ADJUST
MENU No.13 ”B-Y (COMPONENT) LEVEL”.
(5) Rotate the JOG dial to adjust to the specified
value.
(6) Press the JOG dial to store the adjustment
data.
(7) Press the USER 1/2 button to select ADJUST
MENU No.14 ”R-Y LEVEL (COMPONENT)”.
(8) Rotate the JOG dial to adjust to the specified
value.
(9) Press the JOG dial to store the adjustment
data.
*
Y OUT
-
JOG dial
+
1.000Vp-p
*
PB OUT
-
JOG dial
+
B-Y level
0.700 Vp-p
*
PR OUT
-
JOG dial
+
R-Y level
0.700 Vp-p
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
BURST
LEVEL
VIDEO
LEVEL
H-rate
*
VIDEO OUT
-
JOG dial
+
BURST level
NTSC: 0.286 ± 0.015V
PAL: 0.300 ± 0.015V
(4) Press the USER 1/2 button to select ADJUST
MENU No.11 ”LEVEL” .
(5) Rotate the JOG dial to the specified value.
(6) Press the JOG dial to store the adjustment
data.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0.7Vp-p
0.7
Vp-p
Y
B-Y
R-Y
1.0
Vp-p