2-1
SECTION 2
MECHANICAL ADJUSTMENTS
2.1
BEFORE ADJUSTMENTS
2.1.1
Precautions
1) Be sure to apply a screw securing torque when attaching a
part.
The securing torque should be 0.04 N-m (0.4 kgf-cm) unless
otherwise specified.
2) Always unplug the power cord of the set before attaching,
removing or soldering a part.
3) When unplugging a connector, do not pull the wire but grasp
the connector body.
4) Do not make an adjustment or rotate a potentiometer blindly
while the source of trouble is not identified.
5) Before adjusting electrical circuitry, be sure to wait for more
than 10 minutes after turning the power on.
2.1.3
Equipment required for adjustments
Table 2-1-2
1
2
4
5
6
7
3
8
MC-1 (NTSC)
MC-2 (PAL)
YTU94085
YTU94121A
PTS40844-2
YTU94150A (or YTU94151A)
Alignment tape
DV tape
Cassette torque meter
Guide screwdriver
Torque screwdriver
Slit washer attaching tool
Connector board (REWRITE PWB)
CK453800C
Chip IC replacement tool
YTU94088
YTU94088-003
Replaceable bit
(long type)
For use
in self-recording/playback.
(M-DV 63PRO BU)
2.1.2
Measuring instruments required for adjustments
Condition
Calibrated instrument with measuring
bandwidth of 100 MHz or more.
Instrument
Oscilloscope
Table 2-1-1