3-6
No.
Item
Measuring
instruments &
Input signals
Mode
Measuring point (
*
)
Adjustment parts (
-
)
Adjustment level (
+
)
Adjustment procedure
Oscilloscope
*
VIDEO OUT
-
JOG dial
+
Minimize the carrier
leak
*
VIDEO OUT
-
JOG dial
+
Minimize the carrier
leak
(1) Press the USER 1/2 button to select ADJUST
MENU No.20 ”FPGA BLACK (B)”.
(2) Rotate the JOG dial to adjust to the specified
value.
(3) Press the JOG dial to store the adjustment
data.
(4) Then, Press the USER 1/2 button to select
ADJUST MENU No.21 ”FPGA BLACK (R)”.
(5) Rotate the JOG dial to adjust to the specified
value.
(6) Press the JOG dial to store the adjustment
data.
*
VIDEO OUT
+
Less than 0.03Vp-p
(10) Check the CHROMA signal to confirm that
the carrier leakage should be specified level.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
4
BLACK
adjustment
ADJUST MENU
Oscilloscope
*
VIDEO OUT
-
JOG dial
+
0.053 ± 0.007V
(7) Then, press the USER 1/2 button to select
ADJUST MENU No.22 ”MASTER BLACK”.
(8) Rotate the JOG dial to adjust black level to the
specified value.
MASTER
BLACK
adjustment
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
minimum
0.053V
5
CLAMP
LEVEL
adjustmen
Lens cap
ADJUST MENU
*
LCD monitor
-
JOG dial
+
[G] L Ref.: 127 or 128
(1) Press the USER 1/2 button to select ADJUST
MENU No. 301 "CLAMP LEVEL[G]L".
(2) Rotate the JOG dial to the specified value.
(3) Press the JOG dial to store the adjustment
data.
A D J U S T [ N T S C ]
* * *
. C L A M P
L E V E L [
*
]
*
.
*
6 5
1
:
T
U
O
L
T
C
5
0
2
:
A
T
A
D
T
E
S
V R
D A T A
:
1 5 5
:
:
B
G
:
R
X
X
X
X
X
X
X
X
X
. L
F
E
R
X
X
X
X
X
X
X
X
X
. R
F
E
R
*
LCD monitor
-
JOG dial
+
[G] L Ref.: 127 or 128
(4) Press the USER 1/2 button to select ADJUST
MENU No. 302 "CLAMP LEVEL[G]R".
(5) Rotate the JOG dial to the specified value.
(6) Press the JOG dial to store the adjustment data.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
(9) Press the JOG dial to store the adjustment
data.
NOTE:
At first, set the level over than the speci-
fied value.
And adjust the level of left side becomes
equal to the specified value.
ADJUST MENU