3-7
No.
Item
Measuring
instruments &
Input signals
Mode
Measuring point (
*
)
Adjustment parts (
-
)
Adjustment level (
+
)
Adjustment procedure
*
LCD monitor
-
JOG dial
+
[B] L Ref.: 127 or 128
*
LCD monitor
-
JOG dial
+
[B] R Ref.: 127 or 128
*
LCD monitor
-
JOG dial
+
[R] L Ref.: 127 or 128
*
LCD monitor
-
JOG dial
+
[R] R Ref.: 127 or 128
(7) Press the USER 1/2 button to select ADJUST
MENU No. 303 "CLAMP LEVEL[B]L".
(8) Rotate the JOG dial to the specified value.
(9) Press the JOG dial to store the adjustment
data.
(10) Press the USER 1/2 button to select ADJUST
MENU No. 304 "CLAMP LEVEL[B]R".
(11) Rotate the JOG dial to the specified value.
(12) Press the JOG dial to store the adjustment
data.
(13) Press the USER 1/2 button to select ADJUST
MENU No. 305 "CLAMP LEVEL[R]L".
(14) Rotate the JOG dial to the specified value.
(15) Press the JOG dial to store the adjustment
data.
(16) Press the USER 1/2 button to select ADJUST
MENU No. 306 "CLAMP LEVEL[R]R".
(17) Rotate the JOG dial to the specified value.
(18) Press the JOG dial to store the adjustment
data.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
6
IN GAIN
adjustment
Vectorscope
Gray scale chart
ADJUST MENU
*
LCD display
-
Lens Iris
+
[G] Ref.: 370 ± 5
*
VIDEO OUT
-
JOG dial
+
Position the noise on
the B-Y
L
axis at the
center of the
Vectorscope
*
VIDEO OUT
-
JOG dial
+
Position the noise on
the R-C
Y
axis at the
center of the
Vectorscope
*
VIDEO OUT
-
JOG dial
+
Position the noise at
the center of the
Vectorscope carrier
leak: less than 0.03V
(1) While shooting the gray scale chart, set the
Lens iris so that the [G] ref. data is specified
value.
(2) Press the USER 1/2 button to select ADJUST
MENU No. 41 "IN GAIN(B)".
(3) Rotate the JOG dial to the specified value.
(4) Press the JOG dial to store the adjustment
data.
(5) Press the USER 1/2 button to select ADJUST
MENU No. 42 "IN GAIN(R)".
(6) Rotate the JOG dial to the specified value.
(7) Press the JOG dial to store the adjustment
data.
(8) Repeat the adjustment from (1) to (6) avobe,
adjust such that the position the noise be-
comes center of the Vectorscope.
(9) Check the carrier leak of white window por-
tion is specified value.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
B-Y
L
axis
R
R-C
Y
axis
A D J U S T [ N T S C ]
* * *
. C L A M P
L E V E L [
*
]
*
.
*
6 5
1
:
T
U
O
L
T
C
5
0
2
:
A
T
A
D
T
E
S
V R
D A T A
:
1 5 5
:
:
B
G
:
R
X
X
X
X
X
X
X
X
X
. L
F
E
R
X
X
X
X
X
X
X
X
X
. R
F
E
R
A D J U S T [ N T S C ]
* * *
. C L A M P
L E V E L [
*
]
*
.
*
6 5
1
:
T
U
O
L
T
C
5
0
2
:
A
T
A
D
T
E
S
V R
D A T A
:
1 5 5
:
:
B
G
:
R
X
X
X
X
X
X
X
X
X
. L
F
E
R
X
X
X
X
X
X
X
X
X
. R
F
E
R