5. Stop the operation as soon as the stabiliser leg is almost vertical, lock the stabiliser leg lock (1).
6. If manual operated stabiliser extension: unlock the stabiliser extension with the handle (2) and
retract the stabiliser extension completely.
7. If manual operated stabiliser extension: lock the stabiliser extension with the handle (2).
Crane with non-tiltable legs
1. Raise the stabiliser leg.
2. Retract the stabiliser extension completely. (If manual
operated stabiliser extension: unlock the handle (2).
Retract the stabiliser extension and lock with the
handle (2).
11.2. Electric tiltable seat [option]
To operate the seat up or down.
Push and hold button (1) and operate the switch (2) at the
same time.
WARNING
Do not stand in front of moving parts. They can cause injuries.
Ending crane operation
64
Jonsered 1188S CE