LED status
CAN status (yellow)
OFF
Unit lacks power or will not start.
Slow flash
No communication via CAN-bus.
Rapid flash
Fault in CAN-bus communication in the unit. For the Master-unit: Fault in
Master unit’s CAN-bus communication or in another part of the system.
Steady glow
CAN-bus communication works normally for the unit. For the Master-unit:
CAN-bus communication works normally for the entire system.
LED status
CPU status (green)
OFF
Unit lacks power or will not start.
Slow flash
Standby position or configuration position.
Rapid flash
Internal fault in the unit. For the Master-unit: Fault in the Master unit or in
other units connected to the system.
Steady glow
Unit works normally. For the Master-unit: The entire system works normally
Ground Control Unit (GCU) [option]
The GCU- unit is a controller used together with the
TimberTronics control system. The GCU is connected to
the crane via a cable.
When the GCU is connected, all levers on the main control
valve will be locked and the crane is operated with reduced
speed.
(1) Stop button
(2) Button to be pressed when using the crane operating
buttons.
ཱ
The control system TimberTronics [option]
Jonsered 1188S CE
49