MNP37M03GBV00 Date: 24-11 Rev. 0
Page 72 of 79
Press the OK key and the display will change and show the time during which the
element is enabled in tenths of a second. To increase or decrease the dose, press keys
1 or 2 respectively. Press key 4 to switch between elements: Solenoid valve or beater.
Press CANCEL to exit this programming option, but before you exit the machine it will
indicate whether the modification carried out is correct or incorrect. Should the
modification be incorrect, the modified data will not be taken into account by the
machine.
11.1.18. - OP_35 Production reset.
Press the OK key to access the option. To execute it you need to enter the access code
(1505). When the reset is executed, all prices are programmed at 0.30, and the
associations go back to factory settings, while the codes and levels are reset, as well as
the working mode for each option within each code.
11.1.19. - OP_40 Coin reloading and accounting in change tubes (MDB)
•
Reloading:
When you insert coins in the coin slot, they are only admitted if they
have a destination change tube. The display will show the number of coins in each
tube and the value of the coin inserted. When it reaches the maximum amount, the
coins will be rejected.
Do not reload tubes manually!!
•
Accounting:
to see the accounting data for the change tubes, press keys “1” to “5”.
The display will show the number of coins in the change tubes. “1” corresponds to
the highest value coin, “2” to the next value coin, and so on. If the same coin is
stored in more than one tube, the display will show the sum of the coins in all such
tubes.
11.1.20. - OP_41 Discharging change tubes (MDB)
Press keys “1” to “5” to discharge coins from the tubes. “1” corresponds to the highest
value coin, “2” to the next value coin, and so on. After discharging the coins, the display
will show the number of coins left in the tubes.
Coin discharge motors will only work while the accounting value is not zero.
12. - Troubleshooting.
The following table will help you diagnose the most common machine and compact
failures. It describes a series of anomalies, their possible causes and the steps to take
in solving them or at least in determining as far as possible the cause of such failures
before contacting our technical support service.
Problem
Possible causes
Steps to follow
Coins are not accepted and
the J-2000 display is off.
You cannot access compact
programming mode.
The J-2000 has no power
supply or the wrong power
supply.
Check that the supply
voltage is within the range
admitted by the device
Check continuity of cables
between the machine and
the J-2000.
You can enter programming
mode in the compact but
there is no communication.
Cables are incorrectly
connected.
Connect them properly.
Содержание COFFEEMAR G-500 V2
Страница 1: ...MNP37M03GBV00 Date 24 11 Rev 0 Page 1 of 79 INGL S COFFEEMAR G 500 V2 USER S MANUAL...
Страница 26: ...MNP37M03GBV00 Date 24 11 Rev 0 Page 26 of 79 6 3 Electrical drawings Cabinet electrical drawing...
Страница 27: ...MNP37M03GBV00 Date 24 11 Rev 0 Page 27 of 79 Door electrical drawing...