The pressure pump is equipped with overheating protection.
It is important to mount the spring against the pump so that it will work as a
clamp and the pump tube does not come off
14
13
7
6
3
10
9
1
5
8
4
12
11
2
15
16
After assembling the kit, connect the free end of the food-grade silicone tube
(
No. 13
) which is connected to the water mains inlet solenoid valve (
No. 14
) to the 1/8”
male thread Aixia coupling (
No. 6
) and connect the coupling to the pump.
Bottle water refilling systems.
When you need to refill the water bottle, the most comfortable methods are:
1.
Remove the bottle lid and place a funnel in the neck to refill it from another
container.
2.
Take the water bottle out of the machine and refill it from another container or from
water mains. To take the bottle out more comfortably, do as follows:
-
Remove the bottle cap and pull the silicon tube out.
-
Remove the waste bin (
no. 15
)
-
Remove the plate that holds the waste bin in place (
no. 16
)
-
Take the bottle out of the machine and refill it
-
Replace all the other components in reverse order.