GAMMA VERSUS MANUAL
65
COD. 1257066 Gamma VERSUS Manual v1.13
7.28 Opening function with presence detection
Model
All
Associated
parameters
ID
Description
Type
P54…P5C Switch
X
SWITCH
Description
The opening function with presence detection allows opening the door only if the user
is near her. The closing security contact input is used as presence detector, so the
opening
is not allowed
until this
input is active
(for example
you can use
a magnetic loop vehicle detection connected to this input).
Configuration
To enable this function it is needed to assign the activation to one of the switches by
means of the
P54…P5C
configuration parameters. Once the function assigned to the
switch, it can be activated setting at ON the switch.
Operating
If the function is enabled, if you receive an order to open when the door is closed, the
door
will not open
if
the closing security contact input is not
active (detects presence). After opening the door, the closing security contact will no
longer be used as a presence detector and it will be used as a safety element
during the closing.
Notes
Содержание GAMMA VERSUS M20
Страница 6: ...GAMMA VERSUS MANUAL 6 COD 1257066 Gamma VERSUS Manual v1 13 2 3 Sectional door 2 4 Folding door...
Страница 7: ...GAMMA VERSUS MANUAL 7 COD 1257066 Gamma VERSUS Manual v1 13 2 5 Rolling door 2 6 Fast door...
Страница 75: ...GAMMA VERSUS MANUAL 75 COD 1257066 Gamma VERSUS Manual v1 13...
Страница 78: ...GAMMA VERSUS MANUAL 78 COD 1257066 Gamma VERSUS Manual v1 13...
Страница 79: ...GAMMA VERSUS MANUAL 79 COD 1257066 Gamma VERSUS Manual v1 13...
Страница 108: ...GAMMA VERSUS MANUAL 108 COD 1257066 Gamma VERSUS Manual v1 13 13 SAFETY INSTRUCTIONS FOR MAINTENANCE...