11.
SAFETY INSTRUCTIONS FOR INSTALLATION
· The panel must be installed while the power is disconnected.
· Before installing the panel, remove all unnecessary ropes or chains and disable any equipment such as
locks that is not necessary for the automatic operation.
· Before installing the panel, check that the door is in good mechanical condition, correctly balanced and
that it opens and closes correctly.
· Install the manual unlocking device at a height lower than 1.8m.
· Install any permanent control next to the door away from any moving part and at a minimum height of
1.5m.
· For permanently connected equipment, an easily accessible power disconnection device must be
incorporated into the wiring. It is recommended that this be of the emergency switch type.
· If the control panel is supplied without emergency stop button, this will be incorporated in the installation,
connecting it to the STOP terminal.
· For correct use of the security edge, this must never be activated when the door is fully closed. It is wise
to install the ends of run before activating the edge.
· This equipment can only be handled by a specialist fitter, by maintenance staff or by a suitably trained
operator.
·To connect the power supply and motor wiring, 2.5 mm2 section terminals must be used.
· Use protective goggles when handling the equipment.
· Fuses must only be handled when the appliance is disconnected from the mains.
· The instructions for using this equipment must remain in the possession of the user.
· European door normative EN 12453 and EN 12445 specify the following minimum protection and door
safety levels:
- for single-family dwellings, prevent the door from making contact with any object or limit the force
of contact (e.g. safety band), and in the case of automatic closing, it is necessary to complement
this with a presence detector (e.g. photocell).
- for communal and public installations, prevent the door from making contact with any object or
limit the force of contact (e.g. safety band), and complement this with a presence detector (e.g.
Photocell)
Disconnect the power supply whenever you proceed
to the installation or repair of the control panel.
Содержание GAMMA VERSUS M20
Страница 6: ...GAMMA VERSUS MANUAL 6 COD 1257066 Gamma VERSUS Manual v1 13 2 3 Sectional door 2 4 Folding door...
Страница 7: ...GAMMA VERSUS MANUAL 7 COD 1257066 Gamma VERSUS Manual v1 13 2 5 Rolling door 2 6 Fast door...
Страница 75: ...GAMMA VERSUS MANUAL 75 COD 1257066 Gamma VERSUS Manual v1 13...
Страница 78: ...GAMMA VERSUS MANUAL 78 COD 1257066 Gamma VERSUS Manual v1 13...
Страница 79: ...GAMMA VERSUS MANUAL 79 COD 1257066 Gamma VERSUS Manual v1 13...
Страница 108: ...GAMMA VERSUS MANUAL 108 COD 1257066 Gamma VERSUS Manual v1 13 13 SAFETY INSTRUCTIONS FOR MAINTENANCE...