GAMMA VERSUS MANUAL
11
COD. 1257066 Gamma VERSUS Manual v1.13
4. PARAMETERS
The configurable parameters of the control panels are grouped by parameter type as follows.
All these parameters depend on the installation type, used motor and used safety devices. Furthermore they
depend on the needs of each installation like maneuver timings, speeds of the door, etc…
4.1 ON/OFF Option parameters
The ON/OFF parameters allows enable or disable control panel functions according to the needs of each
installation.
The parameters marked with the file in grey are only read parameters and they cannot be modified.
Num. Value
On/off
Description
01
Autoprogramming
0 – OFF Enables the autoprogramming function.
1 – ON
02
Auto close
0 – OFF Enables the autoclose function.
1 – ON
03
No stop on opening
0 – OFF Enables the non inversion at opening function.
1 – ON
04
Slow speed
0 – OFF Enables the slow speed.
1 – ON
06
Inhib.4cm S.EDGE.CL
0 – OFF Enables the safety edge inhibition function during the last 4cm of the
closing movement.
1 – ON
07
Dead man
0 – OFF Enables the deadman function.
1 – ON
08
SEC.CL inhibition
0 – OFF Enables the closing safety contact inhibition function.
1 – ON
09
FC.OP installed
0 – OFF
Indicates whether, during programming, the panel has found and
memorised a limit switch on opening and, therefore, will act
accordingly. In most cases, it will open until this is found, adding
pulses or time if required.
1 – ON
0A
FC.CL installed
0 – OFF
Indicates whether, during programming, the panel has found and
memorised a limit switch on closure and, therefore, will act
accordingly. In most cases, it will close until this is found, adding
pulses or time if required.
1 – ON
0B
Open mechanical stop
0 – OFF
Indicates whether, during programming, the panel has found and
memorised a mechanical stop on opening and, therefore, will act
accordingly. In most cases, it will open until the mechanical stop is
found, adding pulses or time if required. (Only available in control
panels for DC motors).
1 – ON
0C
Close mechanical stop
0 – OFF
Indicates whether, during programming, the panel has found and
memorised a mechanical stop on closure and, therefore, will act
accordingly. In most cases, it will close until the mechanical stop is
found. (Only available in control panels for DC motors).
1 – ON
0D
HALL mode
0 – OFF Enables the operation by pulses, encoder or Hall, i.e. the position is
controlled by counting pulses.
1 – ON
0E
Time mode
0 – OFF Enables the opertion by Time, i.e. the position is controlled by
counting time.
1 – ON
0F
BackJump Open
0 – OFF Enables the Back Jump after the opening movement is complete.
1 – ON
10
BackJump Close
0 – OFF Enables the Back Jump after the closing movement is complete.
1 – ON
11
Customization ID
0 – OFF Shows the customization number of the control panel.
Содержание GAMMA VERSUS M20
Страница 6: ...GAMMA VERSUS MANUAL 6 COD 1257066 Gamma VERSUS Manual v1 13 2 3 Sectional door 2 4 Folding door...
Страница 7: ...GAMMA VERSUS MANUAL 7 COD 1257066 Gamma VERSUS Manual v1 13 2 5 Rolling door 2 6 Fast door...
Страница 75: ...GAMMA VERSUS MANUAL 75 COD 1257066 Gamma VERSUS Manual v1 13...
Страница 78: ...GAMMA VERSUS MANUAL 78 COD 1257066 Gamma VERSUS Manual v1 13...
Страница 79: ...GAMMA VERSUS MANUAL 79 COD 1257066 Gamma VERSUS Manual v1 13...
Страница 108: ...GAMMA VERSUS MANUAL 108 COD 1257066 Gamma VERSUS Manual v1 13 13 SAFETY INSTRUCTIONS FOR MAINTENANCE...