GAMMA VERSUS MANUAL
19
COD. 1257066 Gamma VERSUS Manual v1.13
5C
Switch 9
28
FIXED FLASH
Configuration to fix flash output to use electronic flash lights
29 CHARGE
MANEUVER
Configuration to enable charge maneuver every 1 hour during 3 seconds.
30 AUTOMATIC
FIRE OPEN
Enables the automatic opening due to the deactivation of the fire alarm signal.
31 DM
BUTTON&RADIO
Configuration dead man function by using buttons or radio (active in OFF
position)
32 CLOSING
DM
MODE
Configuration dead man mode forced in closing maneuver
DB
Switch 10
(*) This function is special and only available in CBX control panel.
4.3.2 Jumpers
Jumper
Function
JP
If cut off does not allows Side-prog programming
4.4 Input parameters
The input parameters allow configuring each available input of the control panel. Each input can have different
values; they are indicated on the third column of the following table.
Num Inputs
Available values - description
5E
IN 1:IN10
0
NO FUNCTION
The input has not got a defined function.
1
S.EDGE.CL
Closing safety edge input (8k2) .
2
S.EDGE.OP
Opening safety edge input (8k2).
5
FC.OP M1
M1 motor opening limit switch input (NC).
6
FC.OP M2
M2 motor opening limit switch input (NC).
7
FC.CL M1
M1 motor closing limit switch input (NC).
8
FC.CL M2
M2 motor closing limit switch input (NC).
9
SEC.OP
Opening security contact input (NC).
10
SEC.CL
Closing security contact input (NC).
11
STOP
Stop pushbutton input (NC).
12
START
Start pushbutton input (NO).
13
OPEN
Open pushbutton input (NO).
14
CLOSE
Close pushbutton input (NO).
15
PEDESTRIAN
START
Pedestrian pushbutton input (NO).
16
PEDESTRIAN
OPEN
Open pedestrian pushbutton input (NO).
17
DEAD MAN OPEN
Open pushbutton input in deadman mode (NO).
18
DEAD MAN CLOSE
Close pushbutton input in deadman mode (NO).
19
DEAD MAN OP-CL
Start pushbutton input in deadman mode (NO).
20
HALL_A MOTOR 1
HALL A for M1 motor input
21
HALL_B MOTOR 1
HALL B for M1 motor input
22
HALL_A MOTOR 2
HALL A for M2 motor input
23
HALL_B MOTOR 2
HALL B for M2 motor input
24
ZERO CROSS
Configuration input as zero pass.
25
PROG
Programming pushbutton input PROG.
26 CURRENT
MOTOR
1
Configuration input as current motor 1.
5F
60
61
62
63
64
Содержание GAMMA VERSUS M20
Страница 6: ...GAMMA VERSUS MANUAL 6 COD 1257066 Gamma VERSUS Manual v1 13 2 3 Sectional door 2 4 Folding door...
Страница 7: ...GAMMA VERSUS MANUAL 7 COD 1257066 Gamma VERSUS Manual v1 13 2 5 Rolling door 2 6 Fast door...
Страница 75: ...GAMMA VERSUS MANUAL 75 COD 1257066 Gamma VERSUS Manual v1 13...
Страница 78: ...GAMMA VERSUS MANUAL 78 COD 1257066 Gamma VERSUS Manual v1 13...
Страница 79: ...GAMMA VERSUS MANUAL 79 COD 1257066 Gamma VERSUS Manual v1 13...
Страница 108: ...GAMMA VERSUS MANUAL 108 COD 1257066 Gamma VERSUS Manual v1 13 13 SAFETY INSTRUCTIONS FOR MAINTENANCE...