GAMMA VERSUS MANUAL
20
COD. 1257066 Gamma VERSUS Manual v1.13
65
27 CURRENT
MOTOR
2
Configuration input as current motor 2.
28
SEC.OP
Magnetic opening security contact input (connected to MTC).
29
RADIO START
Start pushbutton via radio input (NO).
30 STOP
BY
TEMPERATURE
Temperature stop input (thermal).
31
SEC.CL
Magnetic closing security contact input (connected to MTC).
32 SEC.OP
AUTOTEST
Opening security contact with autotest function input (NC). If this input is
used, an autotest output ready to perform autotest functions must be used.
33
SEC.CL AUTOTEST
Closing security contact with autotest function input (NC). If this input is used,
an autotest output ready to perform autotest functions must be also used.
34 S.EDGE.CL
AUTOTEST
Closing safety edge with autotest function input (NC). If this input is used, an
autotest output ready to perform autotest functions must be also used.
35 S.EDGE.OP
AUTOTEST
Opening safety edge with autotest function input (NC). If this input is used,
an autotest output ready to perform autotest functions must be also used.
36 RSENS
DETECTION
Configuration input as RSENS detection.
37 RBAND
OPEN
DETECT
Configuration input as RBAND opening detection.
38 RBAND
CLOSE
DETECT
Configuration input as RBAND closing detection.
39
STOP N.O.
STOP input (NO)
40
OPTO EDGE.CL
Closing optical safety edge input.
41
OPTO EDGE.OP
Opening optical safety edge input.
42 PRESSURE
SWITCH
Configuration input as pressure switch
43 AUTOEDGE.CL
Closing
automatic 8K2/OPTO safety edge input.
44
AUTOEDGE.OP
Opening automatic 8K2/OPTO safety edge input.
45 COURTESY
LIGHT
ON
Courtesy light activation input.
46 OPEN
SLOW
SPEED REF
Configuration input as opening slow speed entering reference.
47 CLOSE
SLOW
SPEED REF
Configuration input as closing slow speed entering reference.
48
OPEN INSIDE
Configuration input as open from inside.
49
FIRE SIGNAL NO
Configuration input as fire signal (Normally Opened)
50
FIRE OPEN
Configuration input as force open signal
51
STEP BY STEP
INPUT
Configuration input as opening/closing sequence by means of the same
button
52 START
RADIO
SEC_DM
Configuration input as START radio that allows dead man mode if security
active
53
OPEN M1
Configuration input as OPEN motor 1
54
CLOSE M1
Configuration input as CLOSE motor 1
55
OPEN M2
Configuration input as OPEN motor 2
56 CLOSE M2
Configuration input as CLOSE motor 2
57
PRESSURE.SW_M2 Configuration input as pressure switch M2
58
FIRE SIGNAL NC
Configuration input as fire signal (Normally Closed)
59
TAMPER
Configuration input as tamper signal
60 AUTOCLOSE
TIME
REG
Configuration input as autoclose time configuration by means of
potentiometer
61 SPEED
REGULATION
Configuration input as speed regulation factor by means of potentiometer
66
67
D9
IN11:IN12
DA
68
M1
current/zerocross
IN
69
M2 current IN
6A
START
pushbutton IN
6B
STOP
pushbutton IN
Содержание GAMMA VERSUS M20
Страница 6: ...GAMMA VERSUS MANUAL 6 COD 1257066 Gamma VERSUS Manual v1 13 2 3 Sectional door 2 4 Folding door...
Страница 7: ...GAMMA VERSUS MANUAL 7 COD 1257066 Gamma VERSUS Manual v1 13 2 5 Rolling door 2 6 Fast door...
Страница 75: ...GAMMA VERSUS MANUAL 75 COD 1257066 Gamma VERSUS Manual v1 13...
Страница 78: ...GAMMA VERSUS MANUAL 78 COD 1257066 Gamma VERSUS Manual v1 13...
Страница 79: ...GAMMA VERSUS MANUAL 79 COD 1257066 Gamma VERSUS Manual v1 13...
Страница 108: ...GAMMA VERSUS MANUAL 108 COD 1257066 Gamma VERSUS Manual v1 13 13 SAFETY INSTRUCTIONS FOR MAINTENANCE...