GAMMA VERSUS MANUAL
58
COD. 1257066 Gamma VERSUS Manual v1.13
7.22 Panic function
Model
All
Associated
parameters
ID
Description
Type
P78…P90 OUT
XX
OUTPUT
PA1…PB0
(TL-CARD-V) OUT XXX
OUTPUT
P50 Panic
active
signal
NUMERIC
Description
The panic function allows activating a special output by pressing during several
seconds a transmitter button. This transmitter has to be programmed on any of the 4
available Motion channels of the control panel integrated receiver.
This can be used to inform a dangerous or emergency situation by means of a
transmitter (thief, medical emergency, etc.)
Configuration
To enable the panic function it is needed to configure any of the available outputs as
“Panic” by means a VERSUS-PROG programming tool. The
P78
to
P90
configuration
parameters are used to configure the control panel outputs and the
PA1
to
PB0
configuration parameter are used to configure the TL-CARD-V extra outputs.
The configured “Panic” outputs will be activated (pulse output) in case of transmitter
long activation is detected. Therefore these outputs can be used to activate any kind of
alarm system. The output is “normally opened” and it changes to “normally closed”
when it is activated. It keeps active for a short period of time (pulse).
To configure the time that is needed to press the transmitter button to activate the
panic signal,
P50
parameter can be used. This parameter can take values from 0 to 20
seconds.
Operating
If any output is configured as “Panic” and a transmitter is programmed on any of the 4
available Motion channels, the control panel checks the holding time of the transmitter
button.
If this time is larger than the configured time it activates the “Panic” outputs to inform
about a dangerous situation.
Notes
As this function uses the transmitter button holding time to activate an emergency
output, radio interferences have to be taken into account, because they can affect to
the “transmitter – control panel” communication.
Содержание GAMMA VERSUS M20
Страница 6: ...GAMMA VERSUS MANUAL 6 COD 1257066 Gamma VERSUS Manual v1 13 2 3 Sectional door 2 4 Folding door...
Страница 7: ...GAMMA VERSUS MANUAL 7 COD 1257066 Gamma VERSUS Manual v1 13 2 5 Rolling door 2 6 Fast door...
Страница 75: ...GAMMA VERSUS MANUAL 75 COD 1257066 Gamma VERSUS Manual v1 13...
Страница 78: ...GAMMA VERSUS MANUAL 78 COD 1257066 Gamma VERSUS Manual v1 13...
Страница 79: ...GAMMA VERSUS MANUAL 79 COD 1257066 Gamma VERSUS Manual v1 13...
Страница 108: ...GAMMA VERSUS MANUAL 108 COD 1257066 Gamma VERSUS Manual v1 13 13 SAFETY INSTRUCTIONS FOR MAINTENANCE...