Page 92
Test voltages (type testing)
300V standard version
Measuring-circuit voltage to
serial interfaces, inputs and outputs
:3700V AC
Current measurement inputs to
serial interfaces, inputs and outputs
:2300V AC
The serial interfaces are
not
isolated from each other!
150V special version
Measuring-circuit voltage to
serial interfaces, inputs and outputs
:2300V AC
Current measurement inputs to
serial interfaces, inputs and outputs
:2300V AC
The serial interfaces are
not
isolated from each other!
Inputs and outputs
Digital outputs
Type
: NPN transistor
Closed-circuit current
: < 1mA
Operating current
: max. 50 mA (not short-circuit proof!)
Operating voltage
: 5 .. 24V DC, max. 27V DC
Switching frequency
as pulse output
: 10Hz (50ms pulse length)
Digital inputs (option)
Current input
: max. 5mA
Input signal applied
: >20V DC, max. 27V DC
Input signal not applied
: <2V DC
Analog outputs (option)
Resolution
: 8Bit
Accuracy
: +- 1.5% vMb.
Load impedance
: max. 300 Ohm
Reaction time
: 1,5 seconds
Operating voltage, external
: 20V..27VDC
Residual ripple
: max. 2V, 50Hz
Technical specifications Part 2
vMb = of the measuring range.