2.1.6 SYSTEM
Figure 2.7 shows SYSTEM part on the front panel and Table 2.7 lists name and function of each part.
Figure 2.7 Front panel (SYSTEM part)
Table 2.7 Name and function of each part on front panel (SYSTEM part)
№
Name
Description
Ref.
①
UTILITIES key
REMOTE CONTROL
HARD COPY
INTENSITY
SYSTEM SETUP
SYSTEM TOOLS
It displays REMOTE CONTROL setting menu which are used
through LAN.
It sets the file name, file type, background color, and color of the
image data generated by COPY key.
It sets the brightness of a waveform, grid, cursor, REF, BACK
LIGHT.
It sets the beep sound, setting when being powered on (SETUP),
selection of header display information, setting for panel lock and
setting concerning various measurements.
It displays the system information, initializes all internal settings,
updates software, and installs options.
Section
3.11.1
②
COPY key
It outputs the image data into the USB memory connected to the
USB terminal.
Section
3.11.2
③
SAVE/RECALL key
It saves (SAVE)/recalls (RECALL)/deletes (DELETE) data from/to
the internal memory/USB memory.
Section
3.11.3
3.11.4,
3.11.8
④
CONFIGURATION key There are 7 connection patterns: i.e., combination of collector/ base/
emitter terminals and collector supply, step generator, and
Common. Selection from 7 patterns is available.
Section
3.11.5
⑤
AUX key
It sets ON/OFF of output to the auxiliary output voltage (AUX
terminal) and the voltage value.
Section
3.11.6
⑥
APPLICATION key
(option)
Vth /hFE SETUP
LIMIT SWEEP
CONSTANT VOLTAGE / CURRENT
COLLECTOR SWEEP DOUBLE
Functions using APPLICATION key require options. Installation of
them from USB memory allows application functions. Three of Vth
/hFE SETUP, LIMIT SWEEP, and CONSTANT VOLTAGE /
CURRENT in four following kinds can be measured by using
Semiconductor parameter search option CS-800.
COLLECTOR SWEEP DOUBLE can be measured by using
DOUBLE SWEEP option CS-801.
It sets the function which automatically measures semiconductor
parameters such as the threshold voltage (Vth) of MOS transistor
and the amplification factor (hFE) of the bipolar transistor.
It sets function which automatically stop SWEEP at the specified
voltage/current.
It is the effective function to make long observation for reliability and
stability of the semiconductor device. Measurement makes either
parameter of Vce and IC constant.
It is a function to observe the characteristic of the semiconductor
devices such as hysteresis. SWEEP can be measured by turning
continuously in the image like start point A
⇒
UP SWEEP
⇒
turning
point B
⇒
DOWN SWEEP
⇒
start point A.
Section
3.11.7
3.11.7.1
3.11.7.2
3.11.7.3
3.11.7.4
Содержание CS-3000 Series
Страница 1: ...Instruction Manual Curve Tracer CS 3000 series CS 3100 CS 3200 CS 3300 ...
Страница 2: ...Ⓒ 2010 IWATSU ELECTRIC CO LTD All rights reserved ...
Страница 16: ......
Страница 170: ......
Страница 210: ...Chapter 4 Characteristics Measurement 4 40 Curve Tracer CS 3000 Series Instruction Manual Memo ...
Страница 214: ...Chapter 5 Daily Maintenance and Calibration 5 4 Curve Tracer CS 3000 Series Instruction Manual Memo ...
Страница 221: ...Chapter 6 Specifications Curve Tracer CS 3000 Series Instruction Manual 6 7 6 3 3 Test fixture CS 302 Unit mm ...
Страница 223: ...Chapter 6 Specifications Curve Tracer CS 3000 Series Instruction Manual 6 9 6 3 5 Test fixture CS 301 190 Unit mm ...