3.7 Setting collector supply
The collector supply generates AC/(SINE) full-wave rectified/DC voltages to be added to the
collector (drain/anode) of a measured device.
3.7.1
VARIABLE knob
3.7.2
MODE/POLARITY key
3.7.3
POWER-WATT key
3.7.4
VOLTS key
3.7.5
ACQUIRE key
3.7.6
LOOPING COMPENSATION key
The setting result is displayed in the setup display area under the waveform display area.
120mW
Max. peak power
30V
Max. peak voltage
2K
Ω
Inner series resistance value
(current limitation resistance)
Mode and polarity
VARIABLE 0.0 % Variable value (output level)
0.0% to 100.0
%
Current limitation resistance
The current limitation resistance value to limit the peak power applied to a measured device is
determined using the maximum peak power and the maximum peak voltage settings as shown
below:
Current limitation resistance
Содержание CS-3000 Series
Страница 1: ...Instruction Manual Curve Tracer CS 3000 series CS 3100 CS 3200 CS 3300 ...
Страница 2: ...Ⓒ 2010 IWATSU ELECTRIC CO LTD All rights reserved ...
Страница 16: ......
Страница 170: ......
Страница 210: ...Chapter 4 Characteristics Measurement 4 40 Curve Tracer CS 3000 Series Instruction Manual Memo ...
Страница 214: ...Chapter 5 Daily Maintenance and Calibration 5 4 Curve Tracer CS 3000 Series Instruction Manual Memo ...
Страница 221: ...Chapter 6 Specifications Curve Tracer CS 3000 Series Instruction Manual 6 7 6 3 3 Test fixture CS 302 Unit mm ...
Страница 223: ...Chapter 6 Specifications Curve Tracer CS 3000 Series Instruction Manual 6 9 6 3 5 Test fixture CS 301 190 Unit mm ...