Commissioning, Startup, Operation, and Shutdown
XHD Installation, Operation, and Maintenance Manual
57
Method
Description
Other
You can use other methods that employ multiple gland or seal chamber
connections. Refer to the mechanical seal reference drawing and seal flush/
cooling piping diagrams.
Packed stuffing box option
WARNING:
Packed stuffing boxes are not allowed in an ATEX-classified environment.
The factory does not install the packing, lantern ring, or split gland.
These parts are included with the pump in the box of fittings. Before you start the pump, you
must install the packing, lantern ring, and split gland according to the Packed stuffing box
maintenance section in the Maintenance chapter.
Connection of sealing liquid for a packed stuffing box
WARNING:
The mechanical seal must have an appropriate seal-flush system. Failure to do so will
result in excess heat generation and seal failure.
NOTICE:
Make sure to lubricate the packing. Failure to do so may result in shortening the life of the
packing and the pump.
You must use an external sealing liquid under these conditions:
• The pumped fluid includes abrasive particles.
• The stuffing-box pressure is below atmospheric pressure when the pump is running with a
suction lift or when the suction source is in a vacuum. Under these conditions, packing is
not cooled and lubricated and air is drawn into pump.
Conditions for application of an external liquid
Condition
Action
The stuffing box pressure is above atmospheric
pressure and the pumped fluid is clean.
Normal gland leaks of 40 to 60 drops per minute is
usually sufficient to lubricate and cool the packing.
You do not need sealing liquid.
The stuffing box pressure is below atmospheric
pressure or the pumped fluid is not clean.
An outside source of clean compatible liquid is
required.
An outside source of clean compatible liquid is
required.
You must connect the piping to the lantern ring
connection with a 40 to 60 drops-per-minute leak
rate. The pressure must be 1.01 kg/cm
2
| 15 psi
above the stuffing box pressure.
Seal the shaft with a packed stuffing box
WARNING:
Packed stuffing boxes are not allowed in an ATEX-classified environment.
Dynamic seals are not allowed in an ATEX-classified environment.
WARNING:
Failure to disconnect and lock out driver power may result in serious physical injury. Never
attempt to replace the packing until the driver is properly locked out.
Pumps are shipped without the packing, lantern ring, or split gland installed. These parts are
included with the box of fittings shipped with each pump and must be installed before startup.
1. Carefully clean the stuffing-box bore .
Содержание Goulds Pumps XHD
Страница 1: ...Installation Operation and Maintenance Manual XHD ...
Страница 2: ......
Страница 27: ...Installation XHD Installation Operation and Maintenance Manual 25 Direct coupled baseplate leveling worksheet ...
Страница 147: ...Parts Listings and Cross Sectionals XHD Installation Operation and Maintenance Manual 145 Figure 130 Optional features ...
Страница 151: ...Parts Listings and Cross Sectionals XHD Installation Operation and Maintenance Manual 149 ...
Страница 153: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 151 ...
Страница 154: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 152 ATEX notification ...
Страница 155: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 153 IECEx Certificate of Conformity ...
Страница 156: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 154 ...
Страница 157: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 155 Chinese Certificate of Conformity ...