Commissioning, Startup, Operation, and Shutdown
XHD Installation, Operation, and Maintenance Manual
56
bearing frame can be found in the ‘Oil Volume Requirements’ section in the ‘Bearing
Maintenance’ / ‘Maintenance’ portion of the IOM.
1. Correct level
Figure 38: Oil lubricated bearings
4. Replace the oil fill pipe plug (319B).
Shaft-sealing options
In most cases, the manufacturer seals the shaft before shipping the pump. If your pump does
not have a sealed shaft, see the Shaft-seal maintenance section in the Maintenance chapter.
NOTICE:
The mechanical seal used in an ATEX classified environment must be properly certified.
The mechanical seal must have an appropriate seal-flush system. Failure to do so will
result in excess heat generation and seal failure.
This model uses these types of shaft seals:
• Cartridge mechanical seal
• Packed-stuffing-box option
Mechanical seal options
Pumps are usually shipped with mechanical seals installed. If they are not, then refer to the
mechanical seal manufacturer's installation instructions.
These are the mechanical seal options for this pump:
• Cartridge mechanical seal
Connection of sealing liquid for mechanical seals
Seal lubrication is required
Seal faces must have liquid film between them for proper lubrication. Locate the taps using the
illustrations shipped with the seal.
If a flushless slurry seal was ordered, then consult manufacturers instructions for seal
lubrication.
Seal flushing methods
You can use these methods in order to flush or cool the seal:
Method
Description
Product flush
Run the piping so that the pump pushes the pumped fluid from the casing and
injects it into the seal gland. If necessary, an external heat exchanger cools the
pumped fluid before it enters the seal gland.
External flush
Run the piping so that the pump injects a clean, cool, compatible liquid directly into
the seal gland. The pressure of the flushing liquid must be 0.35 to 1.01 kg/cm
2
| 5
to 15 psi greater than the seal chamber pressure. The injection rate must be 2 to 8
lpm | 0.5 to 2 gpm.
Содержание Goulds Pumps XHD
Страница 1: ...Installation Operation and Maintenance Manual XHD ...
Страница 2: ......
Страница 27: ...Installation XHD Installation Operation and Maintenance Manual 25 Direct coupled baseplate leveling worksheet ...
Страница 147: ...Parts Listings and Cross Sectionals XHD Installation Operation and Maintenance Manual 145 Figure 130 Optional features ...
Страница 151: ...Parts Listings and Cross Sectionals XHD Installation Operation and Maintenance Manual 149 ...
Страница 153: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 151 ...
Страница 154: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 152 ATEX notification ...
Страница 155: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 153 IECEx Certificate of Conformity ...
Страница 156: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 154 ...
Страница 157: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 155 Chinese Certificate of Conformity ...