Transportation and Storage
XHD Installation, Operation, and Maintenance Manual
13
Table 1: Methods
Pump type
Lifting method
A bare pump without lifting
handles
Use a suitable sling attached properly to solid points like the casing, the
flanges, or the frames.
A bare pump with lifting lugs Use a suitable sling attached to the lifting lugs in the casing and bearing
cartridge.
A base-mounted pump
Use slings under the pump casing and the drive unit, under the base rails,
or through lifting lugs, when provided.
Examples
Figure 1: Example of a proper lifting method
Figure 2: Example of bare pump proper lifting method
Содержание Goulds Pumps XHD
Страница 1: ...Installation Operation and Maintenance Manual XHD ...
Страница 2: ......
Страница 27: ...Installation XHD Installation Operation and Maintenance Manual 25 Direct coupled baseplate leveling worksheet ...
Страница 147: ...Parts Listings and Cross Sectionals XHD Installation Operation and Maintenance Manual 145 Figure 130 Optional features ...
Страница 151: ...Parts Listings and Cross Sectionals XHD Installation Operation and Maintenance Manual 149 ...
Страница 153: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 151 ...
Страница 154: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 152 ATEX notification ...
Страница 155: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 153 IECEx Certificate of Conformity ...
Страница 156: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 154 ...
Страница 157: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 155 Chinese Certificate of Conformity ...