Troubleshooting
XHD Installation, Operation, and Maintenance Manual
139
Alignment troubleshooting
Symptom
Cause
Remedy
Horizontal (side-to-side) alignment cannot
be obtained (angular or parallel).
The driver feet are bolt-bound.
Loosen the pump's hold-down bolts, and
slide the pump and driver until you
achieve horizontal alignment.
The baseplate is not leveled properly and
is probably twisted.
1.
Determine which corners of the base-
plate are high or low.
2.
Remove or add shims at the appropri-
ate corners.
3.
Realign the pump and driver.
Vertical (top-to-bottom) alignment cannot
be obtained (angular or parallel).
The baseplate is not leveled properly and
is probably bowed.
1.
Determine if the center of the base-
plate should be raised or lowered.
2.
Level screws equally at the center of
the baseplate.
3.
Realign the pump and driver.
Assembly troubleshooting
Table 12: Troubleshooting procedure
Symptom
Cause
Remedy
There is excessive shaft end play.
The internal clearance of the bearings is
excessive.
Replace the bearings with a bearing
of the correct type.
The thrust-bearing end cover is loose.
Tighten the screws.
There are too many shims under the thrust
bearing end cover.
Remove the individual shims to ob-
tain the proper thickness.
The runout for the shaft is excessive.
The shaft is bent.
Replace the shaft.
The runout for the bearing-frame flange is
excessive.
The shaft is bent.
Replace the shaft.
The flange of the bearing frame is distorted. Replace the bearing-frame flange.
The runout for the seal-chamber cover is
excessive.
The seal-chamber cover is improperly seat-
ed on the frame.
Replace or re-machine the seal-
chamber cover.
There is corrosion or wear on the seal-
chamber cover.
Replace the seal-chamber cover.
The runout for the impeller wear ring is
excessive.
The shaft is bent.
Replace the shaft.
The wear ring was machined improperly.
Replace or re-machine the impeller.
i-ALERT
®
2 Equipment Health Monitor troubleshooting
To troubleshoot t the i-ALERT
®
2 Equipment Health Monitor, please refer to the i-ALERT
®
2
Equipment Health Monitor IOM or
Symptom
Cause
Remedy
There are no green or red flashing LEDs.
The battery is dead.
Replace the condition monitor.
The unit is deactivated.
Activate the condition monitor.
The unit is malfunctioning.
Consult your ITT representative
for a warranty replacement.
The red LEDs are flashing, but the temperature and
vibration are at acceptable levels.
The baseline is bad.
Check the temperature and vi-
bration levels and reset the con-
dition monitor.
The unit is malfunctioning.
Consult your ITT representative
for a warranty replacement.
Содержание Goulds Pumps XHD
Страница 1: ...Installation Operation and Maintenance Manual XHD ...
Страница 2: ......
Страница 27: ...Installation XHD Installation Operation and Maintenance Manual 25 Direct coupled baseplate leveling worksheet ...
Страница 147: ...Parts Listings and Cross Sectionals XHD Installation Operation and Maintenance Manual 145 Figure 130 Optional features ...
Страница 151: ...Parts Listings and Cross Sectionals XHD Installation Operation and Maintenance Manual 149 ...
Страница 153: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 151 ...
Страница 154: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 152 ATEX notification ...
Страница 155: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 153 IECEx Certificate of Conformity ...
Страница 156: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 154 ...
Страница 157: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 155 Chinese Certificate of Conformity ...