Maintenance
XHD Installation, Operation, and Maintenance Manual
85
Figure 61: Removal of expeller
Remove the seal cover and gland half casing assembly
1. Remove the gland casing and seal cover assembly by supporting the casing assembly with
a hoist hook through the lifting lug.
Figure 62: Removal of seal cover and half gland assembly
2. Remove the pedestal to casing (427L) and (3701) hardware.