Maintenance
XHD Installation, Operation, and Maintenance Manual
88
Figure 68: Impeller removal - metal lined
4. Secure the Volute Liner hook, to the Volute Liner (561) in the proper orientation, as
illustrated below.
Figure 69: Volute liner replacement - alternate orientations
5. Lift the Hook and volute liner and crane into the Gland casing.
6. Be sure to locate the Volute Liner hook and upper and lower keys, and tighten the bolts thru
the key to the hook. This will restrict movement of the volute liner on the hook. Failure to
tighten the keys appropriately may allow the volute liner to rotate while being hoisted into
the gland casing.
Remove the shaft sleeve
1. Remove the shaft sleeve (126) from the shaft (122). Use a short pry bar to gently facilitate
removal, if necessary.
2. Remove the impeller hub o-ring (412A) and shaft sleeve o-ring (412F).
Содержание Goulds Pumps XHD
Страница 1: ...Installation Operation and Maintenance Manual XHD ...
Страница 2: ......
Страница 27: ...Installation XHD Installation Operation and Maintenance Manual 25 Direct coupled baseplate leveling worksheet ...
Страница 147: ...Parts Listings and Cross Sectionals XHD Installation Operation and Maintenance Manual 145 Figure 130 Optional features ...
Страница 151: ...Parts Listings and Cross Sectionals XHD Installation Operation and Maintenance Manual 149 ...
Страница 153: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 151 ...
Страница 154: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 152 ATEX notification ...
Страница 155: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 153 IECEx Certificate of Conformity ...
Страница 156: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 154 ...
Страница 157: ...Certification CE or CE ATEX XHD Installation Operation and Maintenance Manual 155 Chinese Certificate of Conformity ...