Even if inputting the signal to CN2#4 and #5, but the signal output from CN2#1 and #2
does not change, the following errors have been assumed to occur. Errors can be
distinguished by the LED display.
Error details
〔
HBM-201
〕
For drive switching
Description
STATUS
(
Orange
)
STATUS (Orange) details
No teaching setting/During teaching operation/When the transfer surface is being switched
Horizontal surface standby/Tilted surface standby
ERR
(
Red
)
Causes
Recovery
conditions
Recovery
operation
Description
PWR
(
green
)
Stop
(
signals not input
)
When operating on
a tilted surface
−
(
Normal operation
)
Refer to P.41
3Hz blinking
×
3
⇔
OFF for 480ms
When operating on
a horizontal surface
3Hz blinking
×
2
⇔
OFF for 480ms
During
teaching operation
No teaching setting
Teaching setting
incomplete
Teaching setting
complete
Take one of among
the following measures:
Thermal error
Driver card temperature
is 85°C or more, or
MDR temperature is
110°C or more
Driver card temperature
is 75°C or less, and
MDR temperature is
95°C or less
Lock error
MDR has been locked
when switching the
transfer surface
Eliminate the cause of
lock
Low voltage error
The voltage has been
17 V or less for 1sec,
or the power connector
is connected improperly
Supply a voltage of
17 V or more,
or properly connect the
power connector again
MDR
disconnected
MDR connectors
removed
Connect the MDR
connectors
Fuse blown
Driver card fuse blown
Replace the driver card
6-2-2.
About the initial
position setting
(teaching) of the
transfer surface
LED display explanation
〔
HBM-201
〕
Error details
:
ON
:
Blinking
(
1Hz
)
:
Blinking
(
6Hz
)
:
OFF
7.
Maintenance/Inspection
F-RAT-NX75 Annex User Manual for IB-P02F-P-FT
Advanced preparation
Product check
Wiring
Maintenance/Inspection
Appendix
IB-P02F-P-FT settings
Control/Operation
Original notice - U1.1