47
●
LED indication
〔IB-P02F-P-FT〕LED details
7.
Maintenance/Inspection
F-RAT-NX75 Annex User Manual for IB-P02F-P-FT
Advanced preparation
Product check
Wiring
Maintenance/Inspection
Appendix
IB-P02F-P-FT settings
Control/Operation
Original notice - U1.1
LED
* Inside () indicates the
description on label
LED pattern
Description
Green
Red
SENSOR (SEN A/SEN B)
(LED 406 / 407)
ON
-
Sensor input detected
OFF
-
Sensor input not detected
Remote IN (IN1~4)
(LED 402 ~ 405)
ON
-
Remote input detected
OFF
-
Remote input not detected
Remote OUT (OUT1~4)
(LED 410 ~ 413)
ON
-
Remote output detected
OFF
-
Remote output not detected
POWER (POWER)
(LED 419)
ON
-
Control power supply ON
Flash (6Hz)
-
Power supply of DRV board OFF
OFF
-
Control power supply OFF
System Fault (SF)
(LED 420)
-
OFF
No error
-
ON
System fault error
Bus Fault (BF)
(LED 421)
-
OFF
No error
-
ON
Bus fault error
LINK (LAN A / LAN B)
(LED 408 / 409)
OFF
-
Disconnected LAN cable
electrically
ON
-
Connected LAN cable electrically
ACT (ACT1 / ACT2)
(LED 400 / 401)
OFF
-
No sending/receving data
Flash
-
Sending/receving data
LED
LED pattern
Description
Green (MOT A / MOT B)
Red (STS A / STS B)
MOTOR
(MOT A / MOT B /
STS A / STS B)
(LED 415 / 416 / 417 / 418)
OFF
OFF
Motor stop (No error)
ON
OFF
Rotation of a motor
(common to CW and CCW)
Motor port output(*)
ON
Flash (6Hz)
Blown fuse error
OFF
Flash (1Hz)
Motor disconnected error
ON
Flash (1Hz)
Lock error
OFF
ON
Motor or IB-P02 circuit board
thermal error
ON
Flash (1.7s 6Hz×2times)
Back EMF error
Flash Alternately (1Hz)
Flash Alternately (1Hz)
JAM error
Flash Alternately (6Hz)
Flash Alternately (6Hz)
Software error 1
Flash Alternately (2Hz)
Flash Alternately (2Hz)
Software error 2