40
Use HBM-201 to switch the transfer surface.
6.
Control/Operation
F-RAT-NX75 Annex User Manual for IB-P02F-P-FT
The transfer surface can be switched by inputting the signal to CN2#4 and CN2#5.
Roller transfer
→
Carrier wheel transfer
Carrier wheel transfer
→
Roller transfer
Roller transfer
Roller transfer
Carrier wheel transfer
Carrier wheel transfer
PWR
ERR
STATUS
PWR
Run in the roller surface direction
Stop
Green
STATUS
Orange
ERR
Red
PWR
Green
STATUS
Orange
ERR
Red
Run in the carrier wheel surface direction
INPUT1
Roller surface
switch input
OUT1
Roller surface
standby output
OUT2
Carrier wheel surface
standby output
INPUT2
Carrier wheel
surface switch input
( )
( )
( )
( )
INPUT1
Roller surface
switch input
OUT1
Roller surface
standby output
OUT2
Carrier wheel surface
standby output
INPUT2
Carrier wheel
surface switch input
( )
( )
( )
( )
IB-P02F-P-FT
HBM-201
(
M3
)
N/A INPUT1 INPUT2
OUT 1 OUT 2
Refer to CN2
N/A INPUT1 INPUT2
OUT 1 OUT 2
Refer to CN2
Transfer surface status
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Roller
Roller
→
Carrier Wheel
ON
ON
OFF
Carrier Wheel
ON
ON
OFF
3H
z×
2
OFF
⇔
OFF
OFF
PWR
ERR
STATUS
Transfer surface status
Output
CN2#4
Output
CN2#5
Input
CN2#1
Input
Output
Output
Input
Input
CN2#2
M3 Drive switching MDR
Run in the roller surface direction
Stop
Run in the carrier wheel surface direction
M3 Drive switching MDR
HBM-201
(
M3
)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Carrier Wheel
Carrier Wheel
→
Roller
Roller
CN2#4
CN2#5
CN2#1
CN2#2
ON
ON
OFF
ON
ON
OFF
⇔
3H
z×
3
OFF
OFF
OFF
Switching the transfer surface
6-2-1.
Switching the
transfer surface
〔
M3:HBM-201
〕
Switching the transfer surface
■
If the signal input stops when the transfer surface is being switched, operation
will be interrupted, and the signal output from both CN2#1 and #2 will stop. When
inputting the signal again, operation restarts.
■
After the initial position setting (teaching) of the transfer surface, the roller surface is put on
standby. To put the carrier wheel surface on standby (use it for reception), the transfer
surface needs to be changed by the signal input.
Refer to 6-2-2. About the initial position setting (teaching) of the transfer surface (P.41)
Advanced preparation
Product check
Wiring
Maintenance/Inspection
Appendix
IB-P02F-P-FT settings
Control/Operation
Original notice - U1.1
IB-P02F-P-FT