33
Writing to IB-P02F-P-FT starts.
When writing succeeds, the "Logic download was successful" message is
displayed.
When writing fails, refer to “ICEP” user manual, chapter 10 “troubleshooting”
section 1 “troubleshooting for property setting "
3
■
The IB-P02F-P-FT output will be turned OFF at the time of writing.
■
IB-P02F-P-FT will restart when writing finishes.
■
The ladder logic cannot be written when build is not executed.
Write the ladder logic.
Double-click ‘Property’ for IB-P02F-P-FT (Node), for which the ladder logic is to
be written, on the project tree window to open the property window.
Write the ladder logic to IB-P02F-P-FT.
The created ladder logic will not be applied until it has been written.
Writing the ladder logic
1
Select the created logic, and click ‘Logic DnL’ on the property window.
2
※
When writing the ladder logic for reading to the driver card, check ‘Logic backup’, and click ‘Logic
DnL’.
Since it takes approximately one or two minutes to write the ladder logic for reading (it depends
on the size), we recommend writing only when it is necessary.
Double-click
Writing the ladder logic
6.
Control/Operation
This completes the ladder logic writing.
Do not turn off the power during writing. Also, be sure not to unplug the LAN cable.
Failure to follow this could result in malfunction.
■
When the logic has not been selected (N/A), and “Logic DnL” is clicked,
the logic will not be written, or the existing logic for IB-P02F-P-FT will be
deleted.
F-RAT-NX75 Annex User Manual for IB-P02F-P-FT
Setting the IP address
↓
Creating the project file
↓
Registering IB-P02F-P-FT to be used
↓
IB-P02F-P-FT property settings
↓
Writing properties
Complete
↓
Creating the IB-P02F-P-FT ladder logic
↓
Writing the ladder logic
↓
Advanced preparation
Product check
Wiring
Maintenance/Inspection
Appendix
IB-P02F-P-FT settings
Control/Operation
Original notice - U1.1