Communication extension card
Related function codes
-121-
Function
code
Name
Parameter description
Setting
range
Default
value
P15.14
Transmitted
PZD3
2: Set frequency (×100, Hz)
3: Bus voltage (×10, V)
4: Output voltage (×1, V)
5: Output current (×10, A)
6: Actual output torque (×10, %)
7: Actual output power (×10, %)
8: Rotating speed of the running (×1,
RPM)
9: Linear speed of the running (×1, m/s)
10: Ramp frequency reference
11: Fault code
12: AI1 value (×100, V)
13: AI2 value (×100, V)
14: AI3 value (×100, V)
15: HDIA frequency (×100, kHz)
16: Terminal input state
17: Terminal output state
18: PID reference (×100, %)
19: PID feedback (×100, %)
20: Rated torque of the motor
21: MSB of position reference (signed
number)
22: LSB of position reference (unsigned
number)
23: MSB of position feedback (signed
number)
24: LSB of position feedback (unsigned
number)
25: State word
26: HDIB frequency value (×100, kHz)
27–31: Reserved
0–31
0
P15.15
Transmitted
PZD4
0–31
0
P15.16
Transmitted
PZD5
0–31
0
P15.17
Transmitted
PZD6
0–31
0
P15.18
Transmitted
PZD7
0–31
0
P15.19
Transmitted
PZD8
0–31
0
P15.20
Transmitted
PZD9
0–31
0
P15.21
Transmitted
PZD10
0–31
0
P15.22
Transmitted
PZD11
0–31
0
P15.23
Transmitted
PZD12
0–31
0
P15.24
Temporary
variable 1 used
for transmitted
PZD
0–65535
0–65535
0
P15.25
DP
communication
timeout time
0.0 (invalid)–300.0s
0.0–300.
0
0.0s
P15.26
CANopen
communication
timeout time
0.0 (invalid)–300.0s
0.0–300.
0
0.0s
P15.27
CANopen
communication
baud rate
0: 1000 kbps
1: 800 kbps
2: 500 kbps
0–7
0
Содержание Goodrive350 Series