97
Using View/Add Configuration
View/Add Configuration allows you to associate logical drives with partial and/or multiple
physical arrays (this is called spanning of arrays).
The existing configuration is left intact, so you can also use View/Add Configuration simply
to look at the current configuration.
To use view/add configuration:
1. Choose Configure from the Management menu.
2. Choose View/Add Configuration from the Configure menu. An array selection window
displays showing the devices connected to the current controller.
Hot key information appears at the bottom of the screen. The hot key functions are as
follows:
F2
Display the manufacturer data and MegaRAID error count for the highlighted
drive.
F3
Display the logical drives that have been configured
F4
Designate the highlighted dri ve as a hot spare.
F10
Display the logical drive configuration screen.
3. Press the arrow keys to highlight specific physical drives. Press the spacebar to
associate the highlighted physical drive with the current array. The indicator for the
selected drive changes from READY to ONLIN A[array number]-[drive number]. For
example, ONLIN A2-3 means disk array 2, drive 3.
Add physical drives to the current array as desired. Try to use drives of the same
capacity in a specific array. If you use drives with different capacities in an array, all the
drives in the array is treated as if they have the capacity of the smallest drive in the
array.