122
A RAID 1, 3, or 5 configuration has built-in redundancy. If a drive in a RAID group fails,
the RAID subsystem continues to work but no additional redundancy is provided. Another
drive failure will bring the system down. The failed drive can be replaced and added into the
RAID system by rebuilding the drive. Select Rebuild to perform this function. The rebuild
process can take place while the RAID system is still running, although performance may be
slightly affected.
Abort Rebuild
Select Abort Rebuild to stop the rebuild process at any time. The drive will revert to its
original status before the rebuild began.
Format
Formatting is not supported in Power Console. It is recommended that you format drives
using the MegaRAID BIOS Configuration Utility.
Diagnostics
Select this option to run either internal or external diagnostics on a physical drive that is in a
Ready or Failed state. The external diagnostics divide into two catagories: sequential and
random.
Tools
Choose this option to fail a drive, make a hot spare, enable narrow SCSI, enable wide SCSI,
and perform other actions.
Properties
Choose this option to display drive properties.