159
Error: HDD blinking amber, CHM blinking amber
Reason
Solution
Failed disk drive. Disk array not in
a fault-tolerant state.
Replace the disk drive, rebuild the disk array.
Error: HDD blinking green, CHM steady green
Reason
Solution
Disk drive not assigned into a pack.
Assign the disk drive to a pack, if desired; otherwise,
the hot spare will be used in the event of a disk
failure. Refer to the appropriate chapter that
corresponds to the installed RAID controller.
InterRAID-8 and InterRAID-12
The following tables provide troubleshooting guidelines specifically for the InterRAID-8 and
InterRAID-12 disk arrays.
Error: Information Control Panel displays, “Hardware Error”
Reason
Solution
Component failure.
Identify the failed component using the “Component
Status” menu of the Information Control Panel menu.
Replace the failed component according to Chapter 8.
Error: Power-On Self Test (POST) fails
Reason
Solution
Component failure.
Select “POST Results” in the Information Control
Panel menu. Locate the failed component.