131
6. Review the changes that have been made and select OK when finished.
Adding a Drive
Add Drive from the Advanced Menu of the Logical Drive pulldown menu allows you to add
a physical drive to a configured logical drive.
u
The logical drive state must be Optimal. The physical drive state must be Ready.
u
An Optimal RAID 0 logical drive can be converted to an Optimal RAID 1, RAID 3, or
RAID 5 logical drive by adding one or more physical drives.
u
An Optimal RAID 1 logical drive can be converted to an Optimal RAID 0, RAID 3, or
RAID 5 logical drive.
NOTE
You can also convert between RAID 3 and RAID 5 by adding additional physical drives to the
logical drive.
CAUTION
The state of the physical drive to be added must be Ready. The state of the RAID subsystem
being modified must be Optimal
.
To add a drive:
1. From MegaRAID Power Console, place the cursor on the logical drive where the
physical drive is to be added, and click the right mouse button.
2. Select Advanced Menu from the Logical Drive Menu.
Select Add Drive. The following dialog displays: