72
3. Wait at least 30 seconds; then, restart the InterRAID cabinet and restart the system with
the DACCF diskette in the floppy disk drive.
4. At the command prompt, key in daccf.
5. When the DACCF Main Menu displays, select the Tools option.
6. Select the Backup/Restore Conf option, then select Restore Configuration.
7. Key in the filename for the configuration file. Do not include directory paths. If you
used a .CFG extension as part of the filename, include the extension.
WARNING
Do not key in the filename used for the ASCII version of the RAID configuration file.
The ASCII version will overwrite the binary code for setting the registers, causing
damage to the RAID controller board. The board must be replaced.
8. After restoring the configuration, exit DACCF and restart the system.
Common DACCF Procedures
This section provides a set of common procedures used to configure the disk arrays.
Enabling Automatic Rebuild
The Array Encl MGMT I/F option allows you to hot swap disk drives and automatically
rebuild the replacement disk drive. If Array Encl MGMT I/F is enabled, the RAID
controller detects the replacement drive and automatically begins the rebuild process.
Array Encl MGMT I/F is enabled by default, and must be enabled each time you change the
RAID configuration. RAID configurations for additional disk arrays do not have Array Encl
MGMT I/F enabled by default.
To enable automatic rebuild:
1. Ensure the boot sequence for the system is A:, C:.
2. Insert the DACCF diskette into the floppy disk drive.
3. Restart the system.
4. At the command prompt, key in daccf.
5. If you have multiple RAID controller boards installed in the system, select the controller
to be configured.
6. When the DACCF Main Menu displays, select the Advanced Functions option.
7. Select the Hardware Parameters option.