30
Intel
®
Modular Server System Service Guide
6. Install the backup battery in the black plastic battery holder (see letter “A” in
Figure 17
). Connect the battery cable to the battery connector on the printed circuit
board (see letter “B” in
Figure 17
).
Figure 17. Installing Backup Battery
7. Align notches in the top cover with corresponding tabs in the storage control module.
Slide the top cover forward to close.
8. Secure the top cover to the storage control module with the two screws previously
removed.
9. Re-install the storage control module in the server system. For instructions, see
“Installing a Storage Control Module” on page 26
.
Removing a Backup Battery
To remove a backup battery, follow these steps:
1. Review the safety and ESD information at the beginning of this manual and in the
appendices.
2. Remove the storage control module from the system. For instructions, see
“Removing
a Storage Control Module” on page 27
.
Warning:
You must replace the storage control module with a filler panel or
another storage control module within two minutes.
A
B
AF002440
Содержание MFSYS25V2
Страница 4: ...iv Intel Modular Server System Service Guide ...
Страница 14: ...xiv Intel Modular Server System Service Guide ...
Страница 16: ...xvi Intel Modular Server System Service Guide ...
Страница 82: ...66 Intel Modular Server System Service Guide ...
Страница 137: ...Intel Modular Server System Service Guide 121 Figure 71 Storage Layout Graphical View ...
Страница 143: ...Intel Modular Server System Service Guide 127 Figure 77 Diagnostic Tests Figure 78 System Information Report Download ...
Страница 144: ...128 Intel Modular Server System Service Guide Figure 79 System Information Report ...
Страница 157: ...Intel Modular Server System Service Guide 141 Figure 91 Settings Event Policies Configuration Screen ...
Страница 172: ...156 Intel Modular Server System Service Guide ...
Страница 186: ...170 Intel Modular Server System Service Guide ...
Страница 198: ...182 Intel Modular Server System Service Guide ...