Intel
®
Modular Server System Service Guide
89
You may see one of the following health status descriptions as you move the mouse cursor
over the storage pool icon or the status health icon on the General Tab:
•
Incomplete:
The Storage Pool is missing one or more physical disk drives. This can
occur if the drives in a Storage Pool are transported to another system, but not all the
drives are inserted. You can insert the missing drives, or choose to accept the
incomplete status when prompted.
•
Media Patrol Running:
The storage pool is operational and the media patrol
background task is running (this is a background task that looks for defects).
•
Rebuilding:
The storage pool is rebuilding as a background task.
•
Migrating:
The storage pool has a background task that is expanding the storage pool
or one of the virtual drives.
•
Transitioning:
The storage pool is running a background task that is rebuilding the
storage pool to another drive using a hot spare.
•
Predictive Data Migration Running:
An error detection background task is running.
•
Degraded:
One or more physical disk drives in the storage pool are offline and the
storage pool is operating in a degraded mode.
•
Offline:
All the physical disk drives are offline.
•
Transport Ready:
All the physical disk drives are prepared for transport and can now
be removed from the system.
Storage Pool Actions
The Storage Pool Actions displayed to the right of the system graphic enable an IT
administrator to modify existing storage pools, remotely identify drives contained in a
storage pool and create virtual drives. For a complete list of actions, refer to the following
table.
Table 12. Storage Pool Actions Menu
Global Action Menu Item
Description
Create Storage Pool
Designates one or more drives as a storage pool. Global storage
actions are available at all times on the storage screen.
Selected Storage Pool
Action Menu Items
Description
Rename
Renames an existing storage pool. A dialog box will be displayed
prompting the user for the new storage pool name.
Delete
Deletes an existing storage pool. This action will delete all virtual
drives contained in the selected storage pool and release the drives
for future storage pool configuration.
ALL DATA WILL BE LOST.
Identify
Illuminates the hard drive ID LED, which enables easy onsite
identification of the drives included in the selected storage pool.
Create Virtual Drive
A virtual drive is assigned a name, RAID level, size and server. Once
a virtual drive is created, an operating system can be installed.
Содержание MFSYS25V2
Страница 4: ...iv Intel Modular Server System Service Guide ...
Страница 14: ...xiv Intel Modular Server System Service Guide ...
Страница 16: ...xvi Intel Modular Server System Service Guide ...
Страница 82: ...66 Intel Modular Server System Service Guide ...
Страница 137: ...Intel Modular Server System Service Guide 121 Figure 71 Storage Layout Graphical View ...
Страница 143: ...Intel Modular Server System Service Guide 127 Figure 77 Diagnostic Tests Figure 78 System Information Report Download ...
Страница 144: ...128 Intel Modular Server System Service Guide Figure 79 System Information Report ...
Страница 157: ...Intel Modular Server System Service Guide 141 Figure 91 Settings Event Policies Configuration Screen ...
Страница 172: ...156 Intel Modular Server System Service Guide ...
Страница 186: ...170 Intel Modular Server System Service Guide ...
Страница 198: ...182 Intel Modular Server System Service Guide ...